Advantech INTRAC-305 Manual De Usuario

Descargar
Página de 96
 
INTRAC-305  
OPERATION 
 
© 2011 Advantech Wireless
 
INTRAC-305 MANUAL  -  Issue 3.2 
Page  29 
 
3
 
FINE TUNE  -  sense 
 
    Resolver Sense:
         Azimuth   
>true<
         Elevation  inv
         Pol Angle  inv
1
2
3
4
5
6
(not used)
toggles the highlighted parameter
between ‘true’ and ‘inv’
(not used)
moves the highlight box to the next field
in the current menu
Current Mode     Tracking
Control State    Local
Beac Freq      11.452000 GHz
Beac Level    -10.05     dB
El   Angle     25.37
o
Az   Angle    210.50
o
Pol  Angle     27.4 
o
 
Function
Press EN to accept sense settings
Next 
Field
Change
Resolver
Sense
Home
Standby
puts the antenna control system into
STANDBY mode and skips to the HOME
menu
skips to the Home (root) menu
 
 
 
 
Path 
 
HOME - FUNCTION - SYSTEM SETUP -  
 
 
 
 
MENU KEY 6 (x2) - ENTER 
 
 
 
or 
From Models or Configuration 
 
 
 
 
SYSTEM SETUP - MENU KEY 6 (x2) - ENTER 
 
 
 
Description 
 
This menu allows 
the “sense” of the Azimuth, Elevation and 
Polarisation resolvers to be inverted.  This is necessary to 
allow for different mounting arrangements for the resolvers. 
 
 
 
 
Use Menu Key 6 to step the edit highlight through the three 
angles.  Use Menu Key 4 (Change Resolver Sense) to toggle 
between “true” and “inv.” 
 
 
 
 
Pressing ENTER accepts the settings and moves on to the 
“FINE TUNE - Offsets” menu.  (see next page)