Advantech INTRAC-305 Manual De Usuario

Descargar
Página de 96
 
INTRAC-305  
OPERATION 
 
© 2011 Advantech Wireless
 
INTRAC-305 MANUAL  -  Issue 3.2 
Page  27 
 
3
 
 BEACON THRESHOLD 
 
1
2
3
4
5
6
puts the antenna control system into
STANDBY mode and skips to the HOME
menu
skips to the Home (root) menu
skips to the Models menu
skips to the Config menu
skips to the System Setup menu
(not used)
Current Mode     Tracking
Control State    Local
Beac Freq      11.452000 GHz
Beac Level    -10.05     dB
El   Angle     25.37
o
Az   Angle    210.50
o
Pol  Angle     27.4 
o
 
Standby
Home
Models
Config
System 
Setup
Function
Set Level:      -14.12 dB
Press EN to accept selection
 
 
 
 
Path 
 
HOME - FUNCTION - MENU KEY 6 (x8) - ENTER 
 
 
 
or 
From Models or System Setup 
 
 
 
 
CONFIG - MENU KEY 6 (x8) - ENTER 
 
 
 
Description 
 
On this screen the beacon signal strength at which the 
beacon level alarm trips is set. 
 
 
 
 
If the tracking signal level falls below the value set here the 
INTRAC-305 considers the tracking signal receiver to have 
lost lock on the beacon. 
 
 
 
 
Edit the value in the “Set Level” box using the numeric 
keypad.  The 
 & 
 move the cursor. 
 
 
 
Note 
The only function of the beacon level alarm is to operate a 
relay for external use.  It is not used by the INTRAC algorithm 
and, when it occurs in isolation without an alarm from the 
IBR-L, has no effect on the INTRAC operation or mode.