4.3.1.2 LogData Dump   
 
This command configures the receiver to output all the logged data in NMEA-0183 format or 
binary format. Data logging is disabled upon reception of the command. 
 
Byte # 
Contents 
Range 
Size 
Scale 
Message ID = 0x81 
 
Unsigned byte 
 
Command 
LogDump = 0x12  Unsigned byte 
 
3 Baud 
Rate 
0 =  4800 bps 
1 =  9600 bps 
2 = 19200 bps 
3 = 38400 bps
 
4 Message 
Type 
bit0 = GGA message on/off (0:OFF, 1:ON)   
bit1 = GLL message on/off 
bit2 = RMC message on/off 
bit3 = VTG message on/off 
bit4~6 = reserved 
bit7 = Log binary data on/off
 
 
When bit7 of byte 4 is set, logged data is sent in binary format; otherwise it is sent in NMEA 
format. Bit0 ~ bit3 of byte 4 specifies which NMEA messages to be sent. 
 
4.3.1.3 LogData Erase 
 
This message commands the receiver to erase the logged data stored in the memory. 
 
Byte # 
Contents 
Range 
Size 
Scale 
Message ID = 0x81 
 
Unsigned byte 
 
Command 
LogEarse = 0x11  Unsigned byte 
 
 
4.3.1.4 LogConfig Read 
 
This command retrieves the data logging configuration, and the information on percentage of 
the data buffer used.
 The logging configuration information is returned using private 
message 0x20, described in section 4.3.2.2.
 
 
Byte # 
Contents 
Range 
Size 
Scale 
Message ID = 0x81 
 
Unsigned byte 
 
Command 
LogRead = 0x13 
Unsigned byte