Chapter 3 Creating and Editing Screens 
Revision May, 2010 
 
 
3-151 
Property Description of Dynamic Rectangle Element 
Read Address +2 
The value of the Read Address+2 can be used 
only when Variable Size option is set to Yes. It 
is used to represent the right-bottom 
horizontal position (Right) of the element, i.e. 
the width.   
Read Address +3 
The value of the Read Address+3 can be used 
only when Variable Size option is set to Yes. It 
is used to represent the right-bottom vertical 
position (Bottom) of the element, i.e. the 
height.  
Read Address +4 
The value of the Read Address+4 can be used 
only when Variable Color option is set to Yes. 
It is used to represent the line color. The 
range is different depending on selected HMI. 
The range for 16 shades of gray model is 
within 0 ~ 15, the range for 256 colors model 
is within 0 ~ 255 and the range for 65536 
colors is within 0 ~ 65535. 
Read Address +5 
The value of the Read Address+5 can be used 
only when Blink option is set to Yes. When the 
value is higher than 1, the dynamic line 
element will blink. If the value is 0, it will not 
blink.  
Read Address 
Please note that when Variable Position option is set to No, the 
internal memory address of Variable Size option will increase one 
(one increment) automatically. (Read Address will represent the 
right-bottom horizontal position (Right) of the element. Read 
Address+1 will represent the right-bottom vertical position 
(Bottom) of the element. Read Address+2 will represent the 
foreground color of the element.)   
Blink 
The element can blink to remind the user. (Please refer to Table 
3-8-2 Property Description of General Buttons.) 
Foreground Color 
Used to set the foreground color of the dynamic rectangle 
element. 
Line Size 
The unit is Pixel and the range is within 1 ~ 8. 
Data Format 
It provides BCD, Signed Decimal, Unsigned Decimal and Hex four 
kinds of data format to define the read memory content.