Low initial cost, reliable  operating effi ciency
deliver substantial return on investment
Bryan EB Series Boiler Specifi cations
 
 
                             NOMINAL OUTPUT  
STEAM 
APPROX. 
 
BOILER INPUT 
 
 
OUTPUT  
SHIP WT.
 
MODEL MBH 
(KW)
 
MBH (KW)* 
BHP* 
LBS./HR** (KG) 
LBS. (KG)
 
EB-75 
3,200 (938) 
2,560 (750) 
75 
2,639 (1,197) 
5,810 (2,635)
 
EB-100 
4,200 (1,230) 
3,360 (984) 
100 
3,463 (1,570) 
7,110 (3,225)
 
EB-125 
5,250 (1,538) 
4,200 (1,230) 
125 
4,329 (1,963) 
8,300 (3,765)
 
EB-150 
6,300 (1,845) 
5,040 (1,476) 
150 
5,195 (2,356) 
8,420 (3,819)
 
EB-175 
7,325 (2,146) 
5,860 (1,717) 
175 
6,041 (2,740) 
11,175 (5,069)
 
EB-200 
8,500 (2,490) 
6,800 (1,992) 
200 
7,010 (3,179) 
11,305 (5,128)
 
EB-240 
10,000 (2,930) 
8,000 (2,344) 
240 
8,247 (3,740) 
14,455 (6,557)
NOTES: * 
 
Nominal output based on boiler industry standard of 80% of input. Actual combustion effi ciencies will be fuel dependent.
                  **  Lbs. steam per hour from and at 212° F.
L. Internal water-cooled 
fur nace with low heat 
release rate.
M. Steam boilers with 
extra large drum with high 
steam release area ensure 
stable water level and dry 
steam.
N. Pressurized design: 
inner fi reside casing con-
structed of heavy gauge 
steel, completely seal-
welded, lined with high 
temperature insulation 
and refractory.
J
F
A
E
C
I
B
D
N
L
K
D
M
Quality Construction Features:
A. Water side   or steam side interior  ac cessible 
for clean 
out and inspection, front and rear 
open ings, upper and lower drums.
B. Large volume water leg down comers pro-
mote rapid internal circulation, temperature 
equalization and effi cient heat transfer.
C. Boiler tube and furnace area access panels: 
heavy gauge steel casing with 2
high tem-
perature ceramic fi ber and insulation, bolted 
and tightly sealed to boiler frame.
D. Flame observation port at rear of boiler.
E. Single side access; combustion chamber, tubes and 
burner head are completely accessible from one side 
simplifying maintenance and minimizing fl oor space.
F. Minimum sized fl ue vent. 
G. Control panel: all controls installed with connections 
to terminal strip. 
H. Forced draft, fl ame retention head type burner. Effi -
cient combustion of oil or gas, plus quiet operation. 
I. Heavy steel boiler frame, built and stamped in accor-
dance with the appropriate ASME Boiler Code.
J. Heavy gauge steel boiler jacket with rust-resistant 
zinc coating and enamel fi nish, insulated with 1½
fi berglass to ensure exceptionally cool outer surface.
K. Bryan bent water tubes are flexible, individually 
replaceable without welding or rolling. Never more 
than two tube configurations. 
G
H
• True “fl exible water tube” design
• High quality steam for heat 
 or process
• Pressurized fi ring for maximum 
performance