Bryan Boilers EB-75-S150-FDG Manual De Usuario

Descargar
Página de 4
LEFT SIDE VIEW
REAR VIEW
PLAN VIEW
FRONT VIEW
Bryan EB Series Steam & Hot Water Boilers
Specifi cations subject to change without notice. Consult factory to consult on other boiler options.
Form No. 8100 
©2006 Bryan Steam LLC 
Printed in USA
   
 
16-7447
DIMENSIONS in inches (cm)
  
A  B  C  D 
G  H  I 
L
 Boiler  Length 
Width 
Height 
 
Gas 
  
  
 
 
Clearance 
Min. Tube  Floor to
 Model 
of  Outside
 
Over
 Overall
 Train 
Supply Return
 
Flue
 
Flue
 
 for Servicing 
Removal 
Flow
 Number  Jacket Jacket
 
Jacket
 Length
 Connection 
Nozzle Nozzle
 
Size
 
Location
 Burner Clearance 
Nozzle
 
EB-75-W
 75½  50 87½ 108¼ 
2½ 
12  13¼ 
48 
32 
90
   (191.77) 
(127.00) 
(222.25) 
(274.96) (6.35)  (10.16) (10.16) 
(30.48) 
(33.66) (121.92)  (81.28) 
(228.60)
 
EB-100-W
 
98 
50 
87½ 
130½ 
2 6 6 
16 
16 48 32 
90
   (248.9) 
(127.00) 
(222.25) 
(331.4)  (5.08)  (15.25) (15.25) 
(40.64) 
(40.64) (121.92)  (81.28) 
(228.60)
 
EB-125-W
 111  50  87½  143½ 
2½ 
16  18¾ 
48 
32 
90
   (281.94) 
(127.00) 
(222.25) 
(364.49) (6.35)  (15.25) (15.25) 
(40.64) 
(47.63) (121.92)  (81.28) 
(228.60)
 
EB-150-W
 111  50  87½  143½ 
2½ 
16  18¾ 
48 
32 
90
   (281.94) 
(127.00) 
(222.25) 
(364.49) (6.35)  (15.25) (15.25) 
(40.64) 
(47.63) (121.92)  (81.28) 
(228.60)
 
EB-175-W
 152¾  50  87½  185¼ 
2½ 
18 
18¾ 
48 
32 
90
   (387.99) 
(127.00) 
(222.25) 
(470.54) (6.35)  (15.25) (15.25) 
(45.72) 
(47.63) (121.92)  (81.28) 
(228.60)
 
EB-200-W
 152¾  50  87½  185¼ 
2½ 
18 
18¾ 
48 
32 
90
   (387.99) 
(127.00) 
(222.25) 
(470.54) (6.35)  (15.25) (15.25) 
(45.72) 
(47.63) (121.92)  (81.28) 
(228.60)
 
EB-240-W
 197¾  50  87½  237¼ 
2½ 
20 
20¾ 
48 
32 
90
   (502.3) 
(127.00) 
(222.25) 
(602.6)  (6.35)  (15.25) (15.25) 
(50.8) 
(52.7)  (121.92)  (81.28) 
(228.60)
Steam Heating/
Pr
ocessing Boilers
DIMENSIONS in inches (cm)
 
 
        F 
 
I     
K    
L
 Boiler  Length 
Width 
Height   
Gas 
 
 
Supply   
  
  
     
Clearance 
Min. Tube 
Floor to
 Model 
of Outside
 
Over
 Overall
 Train 
 
 
Nozzle  
Return
 
Flue
 
Flue
  
for Servicing  Removal 
Flow
 Number  Jacket Jacket
 
Jacket
 Length
  Connection 
15 psi 
  150 psi
 Conn.
 
Size
 
Location
 Burner Clearance 
Nozzle
 
EB-75-S
 75½ 55 
100¼ 
108¼  2½ 
6  
2  12  13¼ 
48 
32 
104¾
 
 
(191.77)  (139.70) (254.64) (274.96) 
(6.35) 
(15.25)    (10.16) 
(5.08)  (30.48) 
(33.68) 
(121.92) 
(81.28) 
(266.1)
 
EB-100-S
 98  55 
100¼ 
130½  2 
8  
2  16  16 
48 
32  104¾
   (248.9) 
(139.70) 
(254.64) 
(331.4) 
(5.08) (20.32) 
 
(15.24) 
(5.08) 
(40.64) 
(40.64) (121.92)  (81.28) (266.1)
 
EB-125-S
 111  55 100¼ 
143½  2½ 
8  
2  16  18¾ 
48 
32 
104¾
 
 
(281.94)  (139.70) (254.64) (364.49) 
(6.35) 
(20.32)    (15.24) 
(5.08)  (40.64) 
(47.63) 
(121.92) 
(81.28) 
(266.1)
 
EB-150-S
 111  55 100¼ 
143½  2½ 
8  
2  16  18¾ 
48 
32 
104¾
 
 
(281.94)  (139.70) (254.64) (364.49) 
(6.35) 
(20.32)    (15.24) 
(5.08)  (40.64) 
(47.63) 
(121.92) 
(81.28) 
(266.1)
 
EB-175-S
 152¾  55 100¼ 
185¼ 
2½ 
10  6 
2  18  18¾ 
48 
32 
104¾
 
 
(387.99)  (139.70) (254.64) (470.54) 
(6.35) 
(25.40)    (15.25) 
(5.08)  (45.72) 
(47.63) 
(121.92) 
(81.28) 
(266.1)
 
EB-200-S
 152¾  55 100¼ 
185¼ 
2½ 
10  6 
2  18  18¾ 
48 
32 
104¾
 
 
(387.99)  (139.70) (254.64) (470.54) 
(6.35) 
(25.40)    (15.25) 
(5.08)  (45.72) 
(47.63) 
(121.92) 
(81.28) 
(266.1)
 
EB-240-S
 197¾  55 100¼ 
237¼ 
2½ 
10  6 
2  20  20¾ 
48 
32 
104¾
   (502.3) 
(139.70) 
(254.64) 
(602.6) 
(6.35) (25.40) 
 
(15.25) 
(5.08) 
(50.6) 
(52.7) (121.92)  (81.28) (266.1)
Hot W
ater 
Heating Boilers
PLAN VIEW
FRONT VIEW
LEFT SIDE VIEW
REAR VIEW
Bryan Steam LLC — Leaders Since 1916
  
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone: 765-473-6651 • Internet:www.bryanboilers.com  
Fax: 765-473-3074  • E-mail: bryanboilers@iquest.net