Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 Manual De Usuario

Descargar
Página de 452
158
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide53-1002373-02
Installing a Brocade MLX-4 router
3
Installing Brocade MLX-4 modules
The Brocade MLX-4 router ships with the required switch fabric modules installed.
The sequence for installing multiple modules is important to ensure proper fit. The recommended 
sequence for the Brocade MLX-4 router is to install right-to-left, beginning with the lowest row and 
moving up.
Installation procedures are identical for interface, management, and switch fabric modules. 
Installing 2x100GbE interface modules
For instructions on installing 2x100GbE interface modules, refer to 
NOTE
Because of the possibility of overheating, 2x100GbE interface modules should not be installed in 
the top slot of a Brocade MLX 4-slot or a Brocade NetIron XMR4000 chassis. There are no heat 
limitations for Brocade MLXe devices.
For information about how to disable and re-enable power to interface modules, see 
DANGER
The intra-building ports of the equipment or subassembly is suitable for connection to 
intra-building or unexposed wiring or cabling only. The intra-building ports of the equipment or 
subassembly MUST NOT be metallically connected to interfaces that connect to the outside plant 
(OSP) or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 
or Type 4 ports as described in GR-1089-CORE, Issue 5) and require isolation from the exposed 
OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect 
these interfaces metallically to OSP wiring.
NOTE
Brocade MLX modules are dedicated, which means that you must install them in Brocade MLX 
routers only. If you install a Brocade MLX management module in another Brocade device, or install 
a management module intended for another Brocade device in a Brocade MLX router, the router and 
module will not function properly.
Although management modules are designed to be hot-swappable, you must upgrade the software 
on all interface modules and management modules to the appropriate software release before 
installing them. For more information on the appropriate software release, refer to the Hardware 
Installation Notes that shipped with the management module. 
If you are installing a redundant management module, refer to the chapter titled “Using a Redundant 
Management Module” in the Brocade MLX Series and Brocade NetIron Family Configuration Guide 
for information about how the redundant module works, optional software configurations, and how 
to manage redundancy.
 identifies the router slot numbers where the modules must be installed. An identifying 
label is located on the base of each slot.