Bay Technical Associates RM356 Manual De Usuario

Descargar
Página de 118
Reference Guide for the Model RM356 Modem Router
8-14
Filter Configuration
 
Applying the Filter
When the filter design is finished, you must tell the router where to apply the filter. Apply it as a 
Call Filter in the remote node that reaches your DNS server(s) (usually your ISP node). Go to 
Menu 11.1, Remote Node Profile, and enter the number of the filter under “Call Filter Sets” as 
shown in 
. If you have multiple filters, you can cascade up to four by entering their 
numbers separated by commas. 
Figure 8-6 shows the Remote Node Profile Menu.
Figure 8-6.
Remote Node Profile Menu
When you finish, restart the router.
Menu 11.1 - Remote Node Profile
     Rem Node Name= MyISP                 Edit PPP Options= No
     Active= Yes                          Rem IP Addr= 0.0.0.0
     Call Direction= Outgoing             Edit IP= No
     Incoming:                            Telco Option:
       Rem Login=                           Transfer Type= 64K
       Rem Password= ********               Allocated Budget(min)= 0
       Rem CLID= N/A                        Period(hr)= 0
       Call Back= N/A
     Outgoing:                            Session Options:
       My Login= netgear                    Input Filter Sets=
       My Password= ********                  Output Filter Sets=
       Authen= CHAP/PAP                     Call Filter Sets= 1  <<- APPLY
       Pri Phone #= 18005551212             Idle Timeout(sec)= 300
       Sec Phone #=
                  Press ENTER to Confirm or ESC to Cancel: