ULTRA-DI PRO DI4000 User Manual
Before you switch on the unit, check that it is configured to match your AC 
mains voltage requirements. If it does not comply, then it is necessary to switch 
the operating voltage to the correct supply requirements BEFORE turning on 
the unit, otherwise the unit could be severely damaged. You will find this 
combined fuse holder/voltage selector at the back, adjacent to the IEC receptacle. 
IMPORTANT: This does not apply for general export models which are 
built for one operating voltage only. 
The AC voltage selection is defined by the position of the fuse holder. If you 
intend to change the operating voltage, remove the fuse holder and twist it 
by 180 degrees before you reinsert it. Matching the two markers shows the 
selected voltage.
◊ 
If the unit is switched to another operating voltage, the fuse rating 
must be changed. See the technical specifications in the appendix.
A safety fuse protects the unit from serious defects. If the fuse blows, this is a 
warning sign and always indicates that the circuit is overloaded. The fault must 
always be repaired before the fuse is replaced. If the safety fuse is faulty and 
needs replacing after the unit is repaired, please make sure that you replace it 
only with the identical type and rating. NEVER use fuses of different ratings or 
cover faulty fuses with aluminium foil. This can cause fire and electric shocks and 
will endanger your life and the lives of others.
3.3  Audio connections
As standard, the BEHRINGER ULTRA-DI PRO is installed with transformer-
balanced outputs. This transformer features automatic hum and noise 
reduction for balanced signals and thus allows for trouble-free operation, 
even at high operating levels. Externally induced mains hum etc. will be 
effectively suppressed. 
◊ 
Please ensure that only qualified persons install and operate the 
ULTRA‑DI PRO. During installation and operation the user must have 
sufficient electrical contact to earth. Electrostatic charges might affect 
the operation of the ULTRA‑DI PRO!
Pin 1
t
u
p
n
I
e
l
b
a
C
t
u
p
t
u
O
Pin 2 = (+) Signal
Positive
Pin 3 = (-) Signal
Shield
(+) Signal + Hum
(-) Signal + Hum
Negative
(+) Hum + Signal
(-) Hum + Signal
2 x Signal
Ground
RFI and Hum
= Signal + 6 dB
1
2
3
1
2
3
Fig. 3.1: Compensation of interference with balanced connections
strain relief clamp
sleeve
tip
sleeve
(ground/shield)
Unbalanced use of mono ¼" jack plugs
tip
(signal)
strain relief clamp
sleeve
ring
tip
sleeve
ground/shield
For connection of balanced and unbalanced plugs,
ring and sleeve have to be bridged at the stereo plug.
Balanced use of stereo ¼" jack plugs
ring
cold (-ve)
tip
hot (+ve)