Barco Printer Accessories II Manual De Usuario

Descargar
Página de 19
26-0904001-00 Rev 00.00 
 
16 
SYSMGR 
Description: System Manager Settings 
 
         
Parameters:  
--blkinv (Black Invalid Mode)    : 0=OFF, 1=ON                                              
--vfd (VFD Brightness)             : 0..6 
--opmode (Operation Mode)     : 0=SingleChannel, 1=DualChannel, 
2=3DProcessing 
 
Note:  For the new operating take full effect, you must save settings and reboot the 
unit. 
 --conmode (Encore Connect Mode)   : 0=OFF, 1=ON                                                                                          
 --unitid (Encore Unit ID)                 : 1..32                                                                                               
 --encoreip (Encore IP address)        : xxx.xxx.xxx.xxx 
 
Query Format: SYSMGR --? 
 
Query Response: 
System Manager Settings in the following format 
SYSMGR --blkinv (Black Invalid Mode) --vfd (VFD Brightness) --opmode 
(Operation Mode) --conmode (Encore Connect Mode) --unitid (Encore Unit ID) 
--encoreip (Encore IP Address) 
 
 
UINPUT 
Description: Input Settings 
 
Required parameters: 
--con (connector) 
--itype (input type), for commands to DVI input settings 
 
Parameters:  
--con (connector)  : [0..5], see below for connector numbers.              
--itype (input type)                : 0 = digital, 1 = analog 
--deint (deinterlacing type)     : 0 = MotionAdaptive, 1 = FieldToFrame 
--motion (motion threshold)    : [0..15] 
 
Examples: 
 
 
UINPUT --con 0 --itype 0 --deint 0 
 
(Update DVI (digital in) input, deinterlacing type to Motion Adaptive 
 
Query Format: UINPUT --con (connector) --? 
 
Query Response: 
Input Settings in the following format 
UINPUT --deint (deinterlacing type) --motion (motion threshold) 
             
Connectors: 
0=DVI 
1=HD15 
2=HDMI 
3=DP 
4=SDI1 
5=SDI2 (available when Dual option mezzanine installed)