Problem
Check
Solution
Console shuts off (enters sleep 
mode) while in use
Main console cable integrity
All wires in cable should be intact. Replace cable 
if wires appear crimped or cut.
Main console cable connections/
position
Confirm cable is securely connected and 
properly positioned. Small latch on connector 
should line up and snap into place.
Magnet position (requires shroud 
removal)
Replace flywheel or entire base assembly if you 
do not see a magnet.
RPM Sensor (requires shroud 
removal)
RPM sensor should be aligned with magnet 
and connected to data cable. Re-align sensor 
if necessary. Replace if there is any damage to 
sensor or connecting wire.
Unit operates but Contact HR 
not displayed
HR cable connection at console
Confirm cable is connected securely to console.
Sensor grip
Confirm hands are centered on HR sensors. Hands 
must be kept still with relatively equal pressure 
applied to each side.
Dry or calloused hands
Sensors may have difficulty with dried out or 
calloused hands. A conductive electrode cream 
such as Buh-Bump™ can help make a better 
conduct. Purchase online at medical or large 
fitness stores.
Handlebars
Replace handlebars if tests reveal no other 
issues.
Unit rocks/does not sit level
Leveler adjustment on front 
stabilizer
Level the machine by turning the feet in or out.
Surface under unit
Move machine to level area if adjustments do not 
compensate for unlevel surfaces.
Foot pedals loose/unit difficult 
to pedal
Hardware
Tightly secure all hardware on pedal arm, sub 
pedal arm, and handlebars.
Troubleshooting