Galil COMMAND REFRENNCE DMC-1400 Manual De Usuario

Descargar
Página de 235
136 ● MB 
 
 
 
 
 
 
   DMC-1400 Series Command Reference 
 
n is the number of registers 
 
array[] will hold the response 
MBh = addr, 4, m, n, array[] 
where 
 
m is the starting register number 
 
n is the number of registers 
 
array[] will hold the response 
MBh = addr, 5, m, n   
where 
 
m is the starting bit number 
 
n is  0 or 1 and represents the coil set to off or on. 
MBh = addr, 6, m, n   
where 
 
m is the register number 
 
n is the 16 bit value 
MBh = addr, 7, array[] 
 
where 
 
array[] is where the returned data is stored (one byte per element) 
MBh = addr, 15, m, n, array[] 
where 
 
m is the starting bit number 
 
n is the number of bits 
 
array[] contains the data (one byte per element) 
MBh = addr, 16, m, n, array[] 
where 
 
m is the starting register number 
 
n is the number of registers 
 
array[] contains the data (one 16 bit word per element) 
MBh = addr, 17, array[]   
where 
 
array[] is where the returned data is stored 
USAGE:    
While Moving 
Yes 
Default Value 
In a Program 
Yes 
Default Format 
Command Line 
Yes 
 
 
Controller Usage 
DMC-1415/1416/1425