Ecom Instruments Lite-Ex LED 30 Manual De Usuario
Ta b l e o f a p p r o v e d b a t t e r y t y p e s
Manufacturer
Type
Duracell Alkaline
MN9100
Varta
Electronics 4001
Eveready Battery
Company, Inc.
Company, Inc.
Energizer E90
Battery life:
approx. 80 h (continuous use)
Dimensions:
140 x 26 mm (l x
ø
)
Weight:
approx. 160g (with batteries)
EC-Designation:
0102
Light source:
Type:
Type:
Gallium-Nitrit-LED
(NSPW500BS)
(NSPW500BS)
Life expectancy:
100.000 operating hours
7. Use and Application /
Operating Instructions
Before use, please read these
operating instructions very carefully
in order to familiarise yourself with
your Lite-Ex LED 30.
For you own safety and information,
please read the following instructions.
operating instructions very carefully
in order to familiarise yourself with
your Lite-Ex LED 30.
For you own safety and information,
please read the following instructions.
7.1 Commissioning
In order to be able to use the torch in the
Ex-hazardous area, you must first check
that the base cap is tightly fastened and
that the safety screw is securely and
completely fitted. After checking these
points the torch can be used in the Ex-
hazardous areas – operation is by
pressing the switch.The torch is supplied
with factory fitted batteries.
In order to be able to use the torch in the
Ex-hazardous area, you must first check
that the base cap is tightly fastened and
that the safety screw is securely and
completely fitted. After checking these
points the torch can be used in the Ex-
hazardous areas – operation is by
pressing the switch.The torch is supplied
with factory fitted batteries.
7.2 Battery Replacement
When the brightness is no longer satis-
factory and the batteries are to be
replaced, it is strongly recommended
that all 3 batteries should be replaced as
a set. When replacing the batteries
When the brightness is no longer satis-
factory and the batteries are to be
replaced, it is strongly recommended
that all 3 batteries should be replaced as
a set. When replacing the batteries
17
16
4.2 Special conditions for use in
areas of Zone 0 or 21
1. The Lite-Ex LED 30 is only certified
and permitted for used in Zone 0 or 21
providing it is secured to the user with
the provided lanyard/wrist strap.
providing it is secured to the user with
the provided lanyard/wrist strap.
2. The torch unit should be prevented
from being dropped.
3. The torch unit must not be left any-
where or stored in Zones 0 or 21.
4.3 Special conditions in dusty
Ex-areas
1. After each change of batteries, the
torch must be blown out or internally
cleaned with a suitable device.
cleaned with a suitable device.
2. The sealing ring must be checked for
any deterioration or damage.
5. Ex-Data
EC Certificate of Conformity No.:
ZELM 02 ATEX 0104
Ex-Designation:
II 1 G EEx ia IIC T4
II 2 D T90°C IP 52
Approved for Zone 2, 1and 0; equipment
group II, gas group IIC;
explosive gases, vapours or fog,
temperature class T4.
Approved for Zone 22 and 21; equipment
group II, explosive dusts; T90°C
group II, gas group IIC;
explosive gases, vapours or fog,
temperature class T4.
Approved for Zone 22 and 21; equipment
group II, explosive dusts; T90°C
Report Job Identification No.: 3 0 1 5 5 6 2
FM-Certification:
I.S. Class I Division 1 Group A-D T4
FM-Certification:
I.S. Class I Division 1 Group A-D T4
6. Technical Data
Ambient operating
temperature Ta:
-20 ... +50°C
Storage temperature:
-20 ... +60°C
Batteries / power supply: 3 x LR1 as per IEC
(see table of approved battery types)
(see table of approved battery types)
BAL_Lite-Ex 30_8sprach 26.02.2003 8:47 Uhr Seite 16