Activating the Special Operations Mode and Default Settings 
 
Blue Heat/Net Sync includes a push button on the rear of the unit beside the DC power 
connector.  This push button can be used to perform special operations such as resetting the unit 
to its default settings or forcing port scanning in situations where the SCM is not accessible.   
Using the Reset Button to Activate the Special Operations Mode 
 
To activate the Special Operations Mode, hold the reset button while the unit is powering up. 
Hold the button until all the port LEDs blink rapidly and then release the reset button.  The port 
LEDs will continue to flash rapidly after the reset button is released to indicate the Special 
Operations Mode is active.  
 
Selecting a Special Operation 
 
Once the Special Operations Mode has been activated, four operation options are available: 
 
1. 
Abandon the Special Operations Mode 
To abandon the Special Operations Mode without selecting a special operation, press 
and hold the reset button for at least four seconds. While the button is pressed, the 
rapid flashing of the port LEDs will stop. After four seconds, the rapid flashing will 
resume and the reset button can be released.  After the release of the reset button, the 
port LEDs will turn off, indicating that the Special Operations Mode has terminated. 
 
2. 
Cancel a Special Operation 
If you need to cancel a special operation after it has been selected, repeatedly press the 
reset button until all the port LEDs begin to flash rapidly. Then abandon the Special 
Operations Mode by pressing the reset button for four seconds, as explained above.  
 
3. 
Select a Special Operation 
Operations are selected by repeated short presses of the reset button. Each time the 
reset button is pressed it is counted and represented on the port LEDs as a binary 
number with the port 1 LED as the least significant bit 
. Choose the 
operation which you want to perform. If you miss the selection that you want, keep 
pressing the button.  The count starts over again once it reaches 7 (1111 binary). 
 
4. 
Activate a Special Operation 
To activate a selection, press and hold the reset button for at least four seconds. During 
this time the rapid flashing of the port LEDs will stop. Once the rapid flashing resumes 
you can release the reset button. The port LEDs will turn off indicating that the Special 
Operations Mode has been activated.