 19                                                 
                                                                                    
In the above example, a rapidly flashing CPU LED during the boot up process signifies the Blue 
Heat/Net Sync has experienced an error.  Port LEDs 1 through 4 signify which error has 
occurred.   In this case, LED 2 and 3 are on, so the error code is 6. The chart below defines the 
error details for each error code. 
 
 
Table 4: LED Error Codes for Blue Heat/Net Sync 
Error Code and Event 
 
Details 
Suggested Corrective 
Action 
1.  
Loader code in flash is erased. 
 
The regions of flash memory which hold 
the loader code are both erased. (There 
are two redundant loaders in flash that 
can be run). 
This may occur in when 
there are ESD 
disturbances or in 
electrically noisy 
environments. If this error 
persists it may be a 
hardware issue. 
Contact 
2.  
Loader code in flash has a bad CRC. 
 
The regions of flash memory which hold 
the loader code both have CRC errors. 
(There are two redundant loaders in flash 
that can be run). 
See corrective action for 
error code 1. 
3.
  RAM copy of loader code has a bad 
CRC. 
 
The loader code is copied to RAM 
before execution. This error is shown if 
the RAM copy has a CRC error. 
See corrective action for 
error code 1. 
4.
  Configuration Data Space (CDS) areas 
have corrupted data (CRC failure). 
 
The CDS is copied from flash to RAM 
during the beginning of the loader code
If a CRC error is detected in the RAM 
copy, this error is shown. 
See corrective action for 
error code 1.