CAT Titan 250 Manual De Usuario

Descargar
Página de 81
Turbomachinery Package Specification 
Titan 
250 Generator Set 
armature and a three-phase, full-wave, diode-type bridge rectifier that rotates with the 
armature. The pilot exciter is a PMG that rotates with the main generator rotor shaft. It 
feeds the exciter field windings with excitation current and is controlled by the CGCM. 
5.2.7 
Bearing Lubrication System 
The generator is supplied with a force-fed bearing lubrication system consisting of onskid 
piping and a filter strainer. Oil is supplied from the package lube oil system. 
 
Table 3. 
Generator and Associated Equipment Specifications 
Approximate Weight 
Generator (Typical Open Drip Proof) 
45 000 kg (99,200 lb) 
Construction Types 
Open Drip Proof (OPD), Air Cooled 
Standard 
Closed Air Circuit Water-to-Air Cooled (CACW) 
Optional 
Closed Air Circuit, Air Cooled (CACA) 
Optional 
Totally Enclosed Air-to-Air Cooled (TEAAC) 
Optional 
Totally Enclosed Water Air Cooled (TEWAC) 
Optional 
Generator 
Optional Voltage Ratings See Note (a) 
11,000, 12,470, or 13,800 VAC,  
Frequency Ratings 
50 or 60 Hz 
Number of Poles 
Number of Leads 
Connection Wye 
Stator Windings 
Form Wound 
Insulation 
National Electrical Manufacturers Association 
(NEMA) Class F 
Temperature Rise See Note (b) 
NEMA Class B,  
Overload Capacity 
-
150% Rated Current for One Minute 
-110% Rated Current for Two Hours 
Overload Compliance 
NEMA 
Short Circuit Capability 
300% For 10 seconds 
Rotor Balance 
To 125% of Rated Speed 
Maximum Wave Form Deviation 
10% 
Maximum Harmonic Content 
3% 
Telephone Influence Factor (TIF) 
 
Balanced 100 
Residual 75 
Efficiency 
The combined generator, exciter, and regulator 
efficiency at full load is nominally 97%. 
Space Heater 
 
Voltage 
120, 220, 230, or 240 VAC 
Frequency 
50 or 60 Hz 
Phase 1 
Phase 
Vibration Monitoring 
Generator Bearing Driven End 
Displacement Probes, X and Y axis 
Generator Bearing Exciter End 
Displacement Probes, X and Y axis 
Notes: 
(a) 
Other voltages can be provided to meet specific customer requirements. 
(b) 
A 80°C (144°F) temperature rise is based on the generator nameplate rating at 40°C (104°F) 
and a power factor of 0.8 for continuous duty service. 
© 2008 Solar Turbines Incorporated. All rights reserved. 
TPS250GS/908 - Preliminary 
16