CAT Titan 250 Manual De Usuario

Descargar
Página de 81
Turbomachinery Package Specification 
Titan 
250 Generator Set 
10.2 Generator 
Control 
10.2.1 Functional 
Description 
The  Turbotronic  4 control system working in conjunction with the generator’s excitation 
system provides control, monitoring, and protection of the generator and its output. The 
key components are: 
•  Permanent magnet generator (PMG) 
•  Rotating armature-type AC exciter 
•  Full-wave rectifier assembly 
•  CGCM 
Figure 19 provides a simplified layout of these components. The exciter armature is 
mounted on the main generator rotor and generates an AC voltage as it revolves in the 
magnetic flux produced by the stationary field. The stationary field is wound on salient 
poles supported by the stator core or frame. The PMG consists of permanent magnets on 
the generator rotor and a stationary armature, also supported by the generator frame. 
The rotating rectifier assembly rectifies the exciter armature AC output to DC. In turn, the 
DC power is applied to the main generator rotating field windings. The complete exciter is 
enclosed and protected by a removable cover. When the rotor operates at synchronous 
speed, the PMG provides power to the CGCM. The CGCM provides the appropriate 
exciter field current to control the exciter armature output, which is rectified to provide DC 
power to the main generator rotating field winding. 
 
EXCITATION OUTPUT
GENERATOR CIRCUIT 
BREAKER
BUS
EXCITATION POWER
LOAD SHARE LINES
(To other Combined Generator Control 
Module or Load Share Module)
GENERATOR 
ARMATURE 
(Stationary)
GENERATOR 
FIELD
RECTIFIER 
ASSEMBLY
EXCITER 
ARMATURE
EXCITER FIELD 
(Stationary)
GENERATOR 
POTENTIAL 
TRANSFORMERS
GENERATOR 
CURRENT
TRANSFORMERS
CROSS CURRENT 
COMPENSATION
TRANSFORMER
BUS
POTENTIAL 
TRANSFORMERS
GENERATOR
COMBINED GENERATOR CONTROL MODULE
CONTROLNET
To Turbotronic 4 Control Processor
PERMANT
MAGNET
GENERATOR
ROTATI
N
G
 P
O
RTION
 
 
Figure 19.  Typical Generator, Exciter, and Generator Control Module Arrangement 
© 2008 Solar Turbines Incorporated. All rights reserved. 
TPS250GS/908 - Preliminary 
41