Installation (Locating The Water Heater) continued-
 
 
This water heater MUST be installed indoors out of the wind and weather. 
 
This water heater must be located in an area where leakage of the tank, water 
line connections, or the combination temperature and pressure relief valve will 
not result in damage to the area adjacent to the water heater or to lower floors 
of the structure. When such locations cannot be avoided, a suitable drain pan 
must be installed under the water heater.  The drain pan must have a minimum 
length and width of at least 4 in. (10.2 cm) greater than the diameter of the 
water heater and must not restrict proper combustion air flow to the water 
heater.  The drain pan, as described above, can be purchased from your 
plumbing professional.  The drain pan must be piped to an adequate drain.  
The piping must be at least 3/4 inch (1.9 cm) in diameter and pitched for proper 
drainage. 
 
To comply with NSF requirements this water heater is to be: 
a)  Sealed to the floor with sealant, in a smooth and easily cleanable way, 
or 
b)  Installed with an optional leg kit that includes legs and/or extensions 
that provide a minimum clearance of 6” beneath the water heater. 
 
Note: For California installation this water heater must be braced, 
anchored, or strapped to avoid falling or moving during an earthquake.  
See instructions for correct installation procedures.  Instructions may be 
obtained from California Office of the State Architect, 400 P Street, 
Sacramento, CA 95814.
 
 
Minimum Clearances
  
 
This installation shall allow access to the front of the water heater and 
adequate clearance shall be provided for servicing and operating this water 
heater. The water heater may be installed on either a combustible or non-
combustible floor.  If the water heater is to be installed directly on carpeting, it 
shall be installed on top of a metal or wood panel (or equivalent) extending 
beyond the full width and depth of the appliance by at least 3 inches (7.6 cm) in 
any direction or, if the appliance is to be installed in an alcove or closet, the 
entire floor shall be covered by the panel. 
 
 
WARNING
 
Failure to adhere to these installation and operating instructions may 
create a hazard to life and property and will nullify the warranty.