Combustion air supply continued-
 
 
1.  After selecting the proper location for the water heater, cut a 4” (10.2cm) 
diameter hole through the floor and all other layers of flooring and 
sheathing directly beneath the front center of the water heater. 
2.  Insert the air intake into the 4” (10.2cm) diameter hole and fasten to the 
floor with the screws provided. 
3.  Adjust the air intake so the lower tube extends below the underside 
sheathing and secure with the screws provided.  THE BOTTOM OF THE 
AIR INTAKE MUST BE AT LEAST 12” (30.5cm)
 ABOVE THE 
GROUND LEVEL.
 
4.  Seal the openings around the air intake and underside sheathing to resist 
the entrance of rodents. 
5.  Position the water heater so it is centered above the air intake.  (Note:  
The water heater should also be centered with the openings in the 
roof and ceiling to allow for correct assembly of the roof jack to the 
flue tube.)
 
 
The water heater is to be secured in place using the supplied sheet metal 
strapping and screws.  Fasten the base of the water heater to the floor using 
the screws provided.  The perforated metal strapping must be fastened to the 
top of the water heater and to the adjacent walls with the screws provided.  
(See Figure 2) 
 
Venting 
 
 
Make certain the flue baffle is in place and centered in flue tube.  Cut a 7 1/4 
inch (18.5cm) diameter hole in the ceiling and roof directly above the flue of the 
water heater.  Center the water heater beneath the 7 1/4 (18.5cm) inch 
diameter holes in the roof and ceiling for proper alignment of the flue tube and 
roof jack vent.  Apply non-hardening mastic on the roof, around the previously 
cut hole, to form a weather seal with the flashing of the gas vent roof jack 
assembly.  Note:  Only the roof jacks listed in Figure 2 can be used on this 
water heater.  
Insert the 3” (7.62 cm) vent connector extension (shipped 
telescoped) into the gas vent roof jack assembly and down onto the flue pipe 
extruding from the top of the water heater.  Fasten the 3” (7.62 cm) vent 
connector to the flue pipe using the 3” (7.62 cm) clamp provided.  After all 
connections are made, apply a bead of silicone (supplied with vent kit) to all 
vent seams and connections above the flue pipe (some kits may contain 
silicone bands to seal vent joints). 
 
WARNING
 
The vent system must be installed properly.  Failure to properly install the 
vent system could result in property damage, personal injury, or death.