Marvel M18AFWPL Hoja De Especificaciones

Descargar
Página de 56
22
Installation Checks
•  Anti-tip mounting bracket must be installed correctly 
and anchored to prevent cabinet from tipping forward.
•  Module should be engaged in the slots on the module 
positioning brackets and seated on the foam seal with-
out air gaps. Module positioning brackets should not be 
removed.
•  All wires from the lower cabinet to module must be 
securely connected. If a problem is suspected, inspect 
both male and female plugs and ensure that the termi-
nals in the plug are sufficiently forward to engage.
•  Cabinet must be level both side-to-side and front-to-
back. Front leveling legs should rest firmly on the floor.  
Cabinetry on both sides of the cabinet must be secure 
and level to prevent the cabinet from shifting when the 
doors are opened.
•  Doors must not hit adjacent walls or countertops.
•  Gaskets must seal completely. If gaskets seal well, no 
further adjustments need to be made.
•  Do NOT overcrowd the shelves or block cold air ducts.
•  Do NOT install a  freezer shelf closer than 8 inches 
from the interior top. 
 
•  Do NOT allow packages to overhang sides or rear of 
shelves as this will block air circulation, making the  
freezer less efficient.
Common Installation Errors
•  Any air leaks between the module and the cabinet will 
keep the cabinet from operating efficiently.
•  The electric outlet must be located in a manner that will 
not interfere with module to cabinet alignment when the 
unit is pushed into place.
•  Power cord to outlet sitting under the power module will 
create an air leak.
•  Plugs from cabinet not connected to the power module.
•  Floor under products lower than finished floor making 
the unit inaccessible for service. Floor under product 
must be strong enough to support weight of fully loaded  
freezer.
•  Product not anchored properly (to prevent tipping).  
Bracket not secured to rear wall studs.
•  Failure to properly level the cabinet and/or power mod-
ule can result in defrost water overflowing.
INSTALLATION CHECKS/COMMON ERRORS