Vent-a-Hood EPITH18448SS Instruccion De Instalación

Descargar
Página de 6
Page 3
L113 1211A
1 ½”
1 ½”
Island Duct Cover 
Mounting Holes 
(Top View)
�⁄��” Dia.
Installation Details
1)  Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. 
Custom hoods may require additional specification consideration.
2)  When installing an island range hood, it is recommended that the bottom edge of the hood be located no more than 
30” above the cooking surface for optimum performance.
3)  Load-bearing framework in the ceiling is necessary for the installation of an island hood. 
Additional framework construction may be required. Do not attach an island hood to a structure 
that cannot support twice the weight of the hood.
 
If  applicable,  remove  the  duct  cover  from  its  packaging  and  remove  the  hood-mounting 
screws from the base of the duct cover. Install the duct cover to the load-bearing framework 
in the ceiling using appropriate hardware through the four inside corner mounting flanges 
on the top of the duct cover.
4)  Install the duct from the outside of the home down to the location of the exhaust outlet on the top of the transition plus 
1”. This will allow the transition to engage 1” inside of the duct. Consult the connection diagrams (on next page) for 
further details on exhaust outlet placement.
 
Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is listed on the back page 
of this instruction sheet.
 
Transition heights are as follows:
Island Dual Blower (T200): 
8” round duct connects to 9” tall VP565 transition (included).
Island Cluster Blower (T400): 
12” round duct connects to 11 1/4” tall VP564 transition (included).
5)  Prepare a protective surface on the floor or countertop for the hood. Remove the hood from its packaging and place 
it upside-down on the protective surface for access to the inside of the hood.
Shown with duct cover installed (sold separately).