RAK204 SERIES SUB-BASE INSTALLATION AND ELECTRICAL DATA
RAB71/77 WALL CASE
NOTE: TYPE 
E
MOUNTING CLIP MUST
BE USED WITH MOLDED
CASE.
SUB-BASE
MOUNTING CLIP
TYPE “E”
MOLDED
CASE
TYPE “B” SCREW
TYPE “A”
SCREW
TO SECURE
SIDE CHANNELS
TYPE “C”
SCREW
ACCESS PLATES
TYPE “C”
SCREW
GREEN GROUND
SCREW
(TYPE 
C
)
METAL CASE
6
6
SIDE CHANNELS ARE ADJUSTABLE
FROM 13-3/4” TO 2-3/8” IN LENGTH
BY BREAKING OFF SECTIONS OF SIDE
CHANNELS.
NOTE: IF METAL CASE DOES NOT HAVE SCREW HOLES, 5/32” DIA. HOLES MUST
NOTE: 
BE DRILLED 6” FROM EACH SIDE IN FRONT FLANGE. (SEE INSERT).
Electrical wiring may enter the sub-base through any of the knockout holes provided in the sub-base.
Knockout holes in the sub-base access plate may accommodate a receptacle, which allows the use of
a power cord (if permitted by code for the particular installation). A knockout for a circuit breaker, fuseholder or
a disconnect is also provided. See page 21 for description of electrical contents of these sub-bases.
TYPE “A”
TYPE “B”
TYPE “C”
6 REQ’D.
2 REQ’D.
8 REQ’D.
TYPE
USE WITH
“D”
RAB71
TYPE
USE WITH
“E”
RAB77
TYPE “A”
SCREW
     5/32
 DIA. HOLE (SEE NOTE)
 FOR SECURING TYPE “D”
CLIPS TO SLEEVE USING
TYPE “A” SCREWS
SCREW CLIP
TYPE “D”
RAK4002
CHASEWAY OPTION
(Shown Without Chassis and Wall Case For Installation Location Only.)