Monogram ZTD910SFSS Instruccion De Instalación
8
Installation Preparation
INSTALLATION BELOW A COUNTERTOP
*NOTE: When installing the warming drawer below a cooktop, a solid barrier must be
installed at least 1" from the lowest point of the bottom of cooktop burner box to the top
of cutout. Use any solid material such as 1/4" thick plywood. Allow at least 1/4" air gap
between the barrier and the top of the warming drawer. See label on top of the warming
drawer for approved cooktop models.
installed at least 1" from the lowest point of the bottom of cooktop burner box to the top
of cutout. Use any solid material such as 1/4" thick plywood. Allow at least 1/4" air gap
between the barrier and the top of the warming drawer. See label on top of the warming
drawer for approved cooktop models.
Installation below a cabinet drawer:
The warming drawer may be installed beneath a cabinet
drawer. In this installation, a solid barrier should be installed
above the warming drawer to block access. Use any solid
material such as 1/4" thick plywood. Allow at least 1/4"
air gap between the barrier and the top of the warming
drawer. Observe the 5" min. above the floor or 1" above
the toekick minimum installation height.
NOTE: If you are installing in frameless cabinets, it may
be necessary to install 1/2" wide cleats to accept drawer
mounting screws. See drawer to find exact locations
of mounting screws.
drawer. In this installation, a solid barrier should be installed
above the warming drawer to block access. Use any solid
material such as 1/4" thick plywood. Allow at least 1/4"
air gap between the barrier and the top of the warming
drawer. Observe the 5" min. above the floor or 1" above
the toekick minimum installation height.
NOTE: If you are installing in frameless cabinets, it may
be necessary to install 1/2" wide cleats to accept drawer
mounting screws. See drawer to find exact locations
of mounting screws.
Side to Side Installation:
Install two warming drawers in separate cutouts.
Allow 2" min. between cutouts.
Allow 2" min. between cutouts.
Install a Solid Barrier
Below a Cooktop
See Note
1-1/2" Cabinet Top
Side to Side Installation
36"
Countertop
Height
1" Min.*
2"
Min.
9-1/4"
9"
A
7"
25"
23-1/2" Min.
1/4" Air
Gap
Solid Barrier
Electrical Outlet 42" Max.
From Right Side
Install a Solid Barrier and
a 1/4" Air Gap Above
Warming Drawer
Electrical Outlet
16" Max. From
Left Side
Install 2x4 or 2x2 Anti-Tip Block
Against Rear Cabinet Wall 9"
From Floor to Bottom of Block
Electrical Outlet
Flush With Side of
Cabinet 7" Max.
• When installed, the front face of the drawer will
be nearly flush with adjacent cabinetry doors.
• Drawer overlaps will conceal cut edges
on all sides of the opening.
The rough opening for the drawer must be:
– Depth: 23-1/2" min. from inside back to front
– Depth: 23-1/2" min. from inside back to front
of cabinet frame.
– Width: 25-1/2" for 27" wide models,
28-1/2" for 30" wide models.
– Height: 9-1/4".
• 5" min. above floor or 1" above toekick. 23-1/4"
from floor to bottom of cutout is recommended
for under countertop installation.
for under countertop installation.
Installation below a cooktop:
Warming drawers are approved for installation below only
certain specified cooktop models. See the label attached
to the top of the warming drawer for approved models.
A solid barrier and air gap between cooktop and warming
drawer is required. See Note above.
certain specified cooktop models. See the label attached
to the top of the warming drawer for approved models.
A solid barrier and air gap between cooktop and warming
drawer is required. See Note above.
Dimensions
A
ZTD910
28-1/2"
ZKD910
25-1/2"