CellarPro Wine Cellar Refrigeration System Inustraciones Dimensionales
Line Sizing Chart
CellarPro Split Refrigeration Systems
Notes:
(1) Line lengths are expressed in equivalent feet = actual run length + fitting allowances.
(2) Use only dehydrated refrigeration service tubing and refrigeration-grade fittings.
(3) Install refrigeration tubing in accordance with local codes and ASHRAE guidelines.
Suction Line Size by Length (ODS)
Model Liquid
Line
Size
(ODS)
up to 100 Feet
Minimum Suction
Line Insulation
Thickness
(in)
Up to 25 Feet
Between 25 and 50
Feet
Between 50 and
100 Feet
Mini-Split 3000S
1/4
1/2 1/2 1/2 1/2
4000S Split
3/8
1/2 1/2 1/2 1/2
6000S Split
3/8
1/2 1/2 5/8 5/8
8000S Split
3/8
5/8 5/8 5/8 7/8
Page 1 of 1
Line Sizing Chart for CellarPro Split Refrigeration Systems
5/9/2011