CellarPro Wine Cellar Refrigeration System Illustrations

Page de 1
Line Sizing Chart
 
CellarPro Split Refrigeration Systems 
 
Notes: 
(1) Line lengths are expressed in equivalent feet = actual run length + fitting allowances. 
(2) Use only dehydrated refrigeration service tubing and refrigeration-grade fittings. 
(3) Install refrigeration tubing in accordance with local codes and ASHRAE guidelines.
 
Suction Line Size by Length (ODS)
Model Liquid 
Line 
Size 
(ODS) 
up to 100 Feet 
Minimum Suction 
Line Insulation 
Thickness 
(in) 
Up to 25 Feet 
Between 25 and 50 
Feet 
Between 50 and 
100 Feet 
Mini-Split 3000S
1/4
 
1/2 1/2 1/2 1/2 
4000S Split
3/8
 
1/2 1/2 1/2 1/2 
6000S Split
3/8
 
1/2 1/2 5/8 5/8 
8000S Split
3/8
 
5/8 5/8 5/8 7/8 
Page 1 of 1
Line Sizing Chart for CellarPro Split Refrigeration Systems
5/9/2011
http://www.cellarprocoolingsystems.com/line-sizing-chart