Bosch d9412gv3 Manual De Usuario

Descargar
Página de 154
D9412GV3/D7412GV3 | Program Entry Guide | 5.0  AUXPARM 
EN | 136 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
This item determines whether the NIM is supervised. 
If the NIM is supervised, disconnecting it from the 
control panel creates a Trouble SDI 88 Event and the 
keypad annunciates a trouble tone and displays  
SERVC SDI 88
Supervise SDI 92 
Default: 
No 
Selection: 
Yes or No 
Yes 
Supervise the network interface 
module (NIM) at SDI address 92.
 
No 
Do not supervise the network 
interface module (NIM) at SDI 
address 92.
 
This item determines whether the NIM is supervised. 
If the NIM is supervised, disconnecting it from the 
control panel creates a Trouble SDI 92 Event and the 
keypad annunciates a trouble tone and displays  
SERVC SDI 92
 
Trouble SDI 88 or SDI 92 Reports are 
always reported using the account 
number for Area 1. 
 
5.7 Route 
Group 
Parameters 
The RG # Same Network Receiver parameters define 
whether a primary and backup network receiver 
configured within a Route Group are the same 
receiver. This is required to ensure that the 
authentication keys from the control panel to receiver 
are the same when the paths to the receiver use 
different IP Addresses or Port Numbers. These 
parameters also enable the backup path poll time to 
change to the primary poll time in the event of a 
Communication Trouble condition.  This operates 
when the following conditions apply: 
  Both primary and backup devices use 
enhanced communication via an SDI device. 
  Both primary and backup path destinations 
are the same receiver that can be accessed 
from more than one network such as on a 
LAN/WAN and over the Internet (even if they 
have different IP/port settings). 
  Either the primary or the backup path (not 
both) has a Communication Trouble 
condition. 
 
 
 
 
 
RG# Same Network Receiver  
Default: 
No 
Selection: 
Yes or No 
Yes 
The control panel uses the same 
authentication keys to communicate 
with both the primary and backup 
paths that are the same receiver and 
upon detection of a Communication 
Trouble on either the primary or 
backup enhanced communication 
paths, the working path immediately 
changes to the faster poll rate. 
No 
The control panel uses separate 
authentication keys to communicate 
with the primary and backup 
receivers and upon detection of a 
Communication Trouble on either the 
primary or backup enhanced 
communication paths, the working 
path continues to use its configured 
poll rate. 
For Example: This would be used when a DX4020 is 
reporting to a receiver over a LAN/ WAN and a ITS-
DX4020-G is reporting to the same receiver over the 
Internet from the cellular service provider.  This 
configuration also typically has the poll rate for the 
ITS-DX4020-G set to a slower poll rate than the 
primary such as every 4 hours. 
 
In the above example, if there is a 
Communication Trouble Condition on the 
DX4020, then the ITS-DX4020-G will poll 
at the configured poll rate of the DX4020. 
If the poll rate of the DX4020 is set to 5 
minutes or faster, there is a possibility of 
excessive data usage that may exceed 
your data plan with the cellular service 
provider.  Be sure that any 
Communication Trouble events are 
addressed as soon as possible.