WIRING DIAGRAMS
Wiring is subject to change.  Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOL
T
A
G
E
!
DIS
C
ONNECT
 AL
L
 POW
E
R BEF
O
RE
 SERVICI
NG OR IN
S
T
A
L
L
IN
G
 T
H
IS
UNIT
 M
U
L
T
IPL
E
 PO
W
E
R SO
UR
CES M
A
Y BE P
R
ESEN
T
 F
A
IL
URE 
T
O
DO
 SO
 M
A
Y CAUS
E PRO
P
ERTY DAM
A
G
E
PERSO
NAL
 I
N
J
U
R
Y
 O
R
 DE
A
T
H
.
R
YL
 
YELLOW
OR
 
ORANGE
PU
 
PURPLE
GN
 
GREEN
BK
 
BLACK
BR
 
BROWN
WH
 
WHITE
BL
 
BLUE
GY
 
GRAY
RD
 
RED
COLOR
 
CODES:
LOW
 
VOLTAGE
 
(24V)
LOW
 
VOLTAGE
 
FIELD
HI
 
VOLTAGE
 
(115V)
HI
 
VOLTAGE
 
FIELD
NOTES:
1.
 
SET
 
HEAT
 
ANTICIPATOR
 
ON
 
ROOM
 
THERMOSTAT
 
AT
 
0.7
 
AMPS.
2.
 
MANUFACTURER'S
 
SPECIFIED
 
REPLACEMENT
 
PARTS
 
MUST
 
BE
 
USED
 
WHEN
 
SERVICING.
0140F00592
 
REV.
 
A
 
OR
 
(MED
 
LOW)
 
BL
 
(MED)
 
RD
 
(LOW)
GAS
 
VALVE
C
PM
C
G
W
       
INTERNAL
 
TO
INTEGRATED
 
CONTROL
JUNCTION
EQUIPMENT GND
FIELD GND
DIAGNOSTIC
LED
2
 
CIRCUIT
CONNECTOR
HOT
SURFACE
IGNITER
 
OVERCURRENT
PROT.
 
DEVICE
IGNITER
TH
 
(3)
INTEGRATED
CONTROL MODULE
JUNCTION
 
BOX
LINE-H
XFMR-H
IN
T
E
GR
A
T
ED C
O
NT
RO
L
 MO
DU
LE
IN
TE
GRA
T
E
D
 CO
NT
ROL
 MO
DUL
E
GND
DISCONNECT
L
N
OVERCURRENT
 
PROTECTION
 
DEVICE
BR
GY
RD
BL
BK
4.
 
IF
 
HEATING
 
AND
 
COOLING
 
BLOWER
 
SPEEDS
 
ARE
 
NOT
 
THE
 
SAME,
 
DISCARD
 
JUMPER
 
BEFORE
 
CONNECTING
 
BLOWER
 
LEADS. UNUSED
   
BLOWER
 
LEADS
 
MUST
 
BE
 
PLACED
 
ON
 
"PARK"
 
TERMINALS
 
OF
 
INTEGRATED
 
CONTROL
 
OR
 
TAPED.
3.
 
IF
 
ANY
 
OF
 
THE
 
ORIGINAL
 
WIRE
 
AS
 
SUPPLIED
 
WITH
 
THE
 
FURNACE
 
MUST
 
BE
 
REPLACED,
 
IT
 
MUST
 
BE
 
REPLACED
 
WITH
 
WIRING MATERIAL
HAVING
 
A
 
TEMPERATURE
 
RATING
 
OF
 
AT
 
LEAST
 
105
TERMINAL
SWITCH
 
(PRESS.)
5.
 
UNIT
 
MUST
 
BE
 
PERMANENTLY
 
GROUNDED
 
AND
 
CONFORM
 
TO
 
N.E.C.
 
AND
 
LOCAL
 
CODES.
PK
 
PINK
115
 
VAC
 
HOT
 
AND
 
PARK
 
TERMINALS
LINE-H
FLAME
SENSOR
FRONT
 
COVER
PRESSURE
 
SWITCH
N
O
C
GY
BK
PLUG
 
CONNECTION
FIELD
 
SPLICE
SWITCH
 
(TEMP.)
OR
24V THERMOSTAT
CONNECTIONS
GR
GND
115 VAC
24 VAC
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
DOOR
SWITCH
BK
GND
L
N
WH
JUNCTION
 
BOX
1
 
OR
ID
 
BLOWER
PRESSURE
SWITCH
HEAT-H
GND
WH
RD
WH
GND
BURNER
 
COMPARTMENT
BLOWER
 
COMPARTMENT
NOTE
 
4
SEE
N
O
COOL-H
 
BK
 
(HI)
BR
BR
CAPACITOR
YL
WH
YL
BL
PU
 
RD
OR
PK
BK
WH
WH
BLOWER
INDUCED
 
DRAFT
MANUAL
 
RESET
AUXILIARY
 
LIMITS
(1)
 
IN
 
UPFLOW
 
     
BLOW ER
 
DECK
(2)
 
IN
 
C'FLOW
      
BLOW ER
 
HOUSING
C
FS
HI
HE
AT
-H
LO
HEA
T-H
IGNITER
HOT
 
SURFACE
IND
IGN
EAC-H
AIR
 
CLEANER
ELECTRONIC
BLWR
CIRCULATOR
BLWR
ID
FLAME
 
SENSOR
115
 
VAC
TRANSFORMER
40
 
VA
24
 
VAC
GND
RO1
 
(5)
RO2
 
(11)
HLO
 
(1)
HLI
 
(7)
MVC (9)
GND (8)
TR (6)
OR
WH
WH
BL
YL
OR
RD
GR
BR
 
PK
PK
GY
WH
11
5
 V
A

NE
U
T
R
A
L
BK
BK
GY
24
V
 TH
ER
M
O
S
T
A
T
 C
O
NN
EC
TI
O
N
S
MICRO
TO
C
G
Y
W
R
2
WH
OR
BL
YL
OR
OR
GY
PK
RD
OR
GY
WH
XF
M
R
-H
TE
R
M
IN
A
L
S
GY
OR
GR
BR
1
2
3
12
11
10
9
8
7
6
5
4
°C.
 
USE
 
COPPER
 
CONDUCTORS
 
ONLY.
24 VAC
HUMIDIFIER
24
 
VAC
HUMIDIFIER
HUMIDIFIER
PSO
 
(4)
MVL(2)
PS
 
(10)
C
NO
C
NO
FRONT COVER
PRESSURE
 
SWITCH
ID BLOWER
PRESSURE
SWITCH
0
C
7
6
5
4
3
2
1
OFF
               
=
 
CONTROL
 
FAILURE
 
  
STEADY
 
ON
 
=
 
NORMAL
 
OPERATION
  
 
1
 
FLASH
  
     
=
   
2
 
FLASHES
  
=
 
PRESSURE
 
SWITCH
 
STUCK
 
CLOSED
   
3
 
FLASHES
  
=
 
PRESSURE
 
SWITCH
 
STUCK
 
OPEN
  
 
4
 
FLASHES
  
=
 
OPEN
 
HIGH
 
LIMIT
   
5
 
FLASHES
  
=
 
FLAME
 
SENSE
 
WITHOUT
 
GAS
 
VALVE
   
7
 
FLASHES
  
=
 
LOW
 
FLAME
 
SIGNAL
  
 
6
 
FLASHES
  
=
   
CONTINUOUS/RAPID
 
FLASHES
 
=
 
REVERSED
 
115
 
VAC
 
POLARITY
CONTROL
MODULE
INTEGRATED
FUSE
ON
OFF
2ND
STAGE
DELAY
MODE
HEAT
OFF
DELAY
FS
1
2
3
HI
OR
OR
PM
GAS
VALVE
C
HI
MVH (12)
FACTORY
 
SETTINGS
SHOWN
*
*
*
*
SEE
NOTE 6
COOL-H
TO
 
115VAC/
 
 
/60
 
HZ
 
POWER
 
SUPPLY WITH
PU
Y
6. TO RECALL THE LAST 5 FAULTS, MOST RECEN T TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS
 
WHILE IN
    STANDBY
 
(NO THERMOSTAT INPUTS)
BK
L
IN
E
 NE
UT
RA
LS
8
   
8
 
FLASHES
 
 
=
 
CHECK
 
IGNITER
 
OR
 
IMPROPER
 
GROUNDING
GCH9*****X[AA,AB]