Goodman Mfg GCH9 Manual De Usuario

Descargar
Página de 16
16
WIRING DIAGRAMS
Wiring is subject to change.  Always refer to the wiring diagram on the unit for the most up-to-date wiring.
GCH9*****XAC
HIGH VOL
T
A
G
E
!
DIS
C
ONNECT
 AL
L
 POW
E
R BEF
O
RE
 SERVICI
NG OR IN
S
T
A
L
L
IN
G
 T
H
IS
UNIT
 M
U
L
T
IPL
E
 PO
W
E
R SO
UR
CES M
A
Y BE P
R
ESEN
T
 F
A
IL
URE 
T
O
DO
 SO
 M
A
Y CAUS
E PRO
P
ERTY DAM
A
G
E
PERSO
NAL
 I
N
J
U
R
Y
 O
R
 DE
A
T
H
.
R
YL YELLOW
OR ORANGE
PU PURPLE
GN GREEN
BK BLACK
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED
COLOR CODES:
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
HI VOLTAGE FIELD
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
0140F00647 REV. B
 OR (MED LOW)
 BL (MED)
 RD (LOW)
GAS VALVE
C
PM
C
G
W
       INTERNAL TO
INTEGRATED CONTROL
JUNCTION
EQUIPMENT GND
FIELD GND
DIAGNOSTIC
LED
2 CIRCUIT 
CONNECTOR
HOT
SURFACE
IGNITER
 OVERCURRENT
PROT. DEVICE
IGNITER
TH (3)
INTEGRATED 
CONTROL MODULE
JUNCTION BOX
LINE-H
XFMR-H
IN
TEG
R
A
T
ED 
C
O
NT
ROL 
MOD
U
LE
IN
TE
GR
A
T
ED
 CO
NTR
O
MODU
L
E
GND
DISCONNECT
L
N
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.
OVERCURRENT PROTECTION DEVICE
OR
GY
RD
BL
BK
4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED
   BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105
TERMINAL
SWITCH (PRESS.)
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
PK PINK
115 VAC HOT AND PARK TERMINALS
LINE-H
FLAME 
SENSOR
FRONT COVER
PRESSURE SWITCH
( SINGLE CONTROL ON 45K BTU )
N
O
C
GY
BK
PLUG CONNECTION
FIELD SPLICE
SWITCH (TEMP.)
OR
24V THERMOSTAT
CONNECTIONS
GR
GND
115 VAC
24 VAC
BLOWER 
COMPARTMENT 
DOOR SWITCH
(OPEN WHEN 
 DOOR OPEN) 
DOOR
SWITCH
WARNING:DISCONNECT POWER BEFORE 
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
BK
GND
DISCONNECT
L
N
WH
JUNCTION
 BOX
1
 OR
ID BLOWER 
PRESSURE 
SWITCH
HEAT-H
GND
WH
RD
WH
GND
BURNER COMPARTMENT
BLOWER COMPARTMENT
NOTE 4
SEE
N
O
COOL-H
 BK (HI)
BR
BR
CAPACITOR
YL
WH
YL
CONTROL
PRIMARY LIMIT
AUTO RESET
BL
PU
MANUAL RESET ROLLOUT LIMIT CONTROL(S)
 RD
OR
PK
BK
WH
WH
BLOWER
INDUCED DRAFT
C
CIRCULATOR 
BLOWER
FS
HI
 
HE
AT
-H
LO
 
HE
AT-
H
IGNITER
HOT SURFACE
IND
IGN
EAC-H
AIR CLEANER
ELECTRONIC
BLWR
CIRCULATOR
BLWR
ID
FLAME SENSOR
115 VAC
TRANSFORMER
40 VA
24 VAC
GND
LIMIT CONTROL
AUTO RESET PRIMARY
(SINGLE CONTROL ON 45K BTU)
LIMIT CONTROL(S)
MANUAL RESET ROLLOUT
RO1 (5)
RO2 (11)
HLO (1)
HLI (7)
MVC (9)
GND (8)
TR (6)
OR
WH
WH
BL
YL
OR
RD
GR
BR
 PK
PU
GY
WH
115
 VA
C
 NE
UT
RA
L
BK
BK
GY
24
V
 T
HER
MOST
A
CON
N
E
C
TI
ONS
MICRO
TO
C
G
Y
W
R
TRANSFORMER
40 VA
2
WH
OR
BL
YL
OR
OR
GY
PU
RD
OR
GY
WH
XF
M
R
-H
TE
R
M
IN
A
L
S
GY
OR
GR
BR
1
2
3
12
11
10
9
8
7
6
5
4
WARNING: 
°C. USE COPPER CONDUCTORS ONLY.
24 VAC
HUMIDIFIER
24 VAC
HUMIDIFIER
HUMIDIFIER
PSO (4)
PS (10)
0
C
7
6
5
4
3
2
1
OFF               = CONTROL FAILURE
   STEADY ON = NORMAL OPERATION
   1 FLASH       =
   2 FLASHES  = PRESSURE SWITCH STUCK CLOSED
   3 FLASHES  = PRESSURE SWITCH STUCK OPEN
   4 FLASHES  = OPEN HIGH LIMIT
   5 FLASHES  = FLAME SENSE WITHOUT GAS VALVE
 OPEN ROLLOUT OR OPEN FUSE
   7 FLASHES  = LOW FLAME SIGNAL
   6 FLASHES  =
SYSTEM LOCKOUT (RETRIES EXCEEDED)
   CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY
CONTROL
MODULE
INTEGRATED
FUSE
HI
BR
OR
MVH (12)
FACTORY SETTINGS 
SHOWN
TO 115VAC/ 1
Ø /60 HZ POWER SUPPLY WITH
GY
Y
6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN
    STANDBY (NO THERMOSTAT INPUTS)
BK
LI
NE
 NE
UTR
A
L
S
8
   8 FLASHES  = CHECK IGNITER OR IMPROPER GROUNDING
PU
GY
(HONEYWELL)
NO
C
C
PRESSURE SWITCH
FRONT COVER
NO
AUXILIARY LIMIT CONTROLS
HI
C
VALVE
GAS
PM
MVL(2)
ID BLOWER
PRESSURE
SWITCH
ON
OFF
2ND 
STAGE 
DELAY
MODE
HEAT 
OFF 
DELAY
FS
1
2
3
*
*
*
*
SEE 
NOTE 6
COOL-H