Mitsubishi Electronics C64T Manual De Usuario

Descargar
Página de 317
10.  PLC Constants 
10.1  PLC Timer 
 
 
278 
10.  PLC Constants 
10.1  PLC Timer 
(SETUP PARAM 6. 1/6) to (SETUP PARAM 6. 2/6) 
PLC device 
Item 
Details 
Setting range 
6000 
 
 
 
 
6015 
T000 
 
 
 
 
T015 
10ms adding 
timer <10ms> 
Set the time for the timer used in the PLC 
program (ladder). 
(Note) This setting value is valid when 
parameter "#6449 bit0" in the 
following "[BIT SELECT]" is set 
to "0". 
0 to 32767 (
×10ms) 
6016 
 
 
 
 
6095 
T016 
 
 
 
 
T095 
100ms adding 
timer <10ms> 
Set the time for the timer used in the PLC 
program (ladder). 
(Note) This setting value is valid when 
parameter "#6449 bit0" in the 
following "[BIT SELECT]" is set 
to "0". 
0 to 32767 (
×100ms)
6096 
 
 
 
 
6103 
T096 
 
 
 
 
T103 
100ms 
cumulative 
timer 
<100ms INC> 
Set the time for the timer used in the PLC 
program (ladder). 
(Note) This setting value is valid when 
parameter "#6449 bit0" in the 
following "[BIT SELECT]" is set 
to "0". 
0 to 32767 (
×100ms)
 
10.2  PLC Counter 
(SETUP PARAM 6. 3/6) 
PLC device 
Item 
Details 
Setting range 
6200 
 
 
 
 
6223 
C000 
 
 
 
 
C023 
Counter 
Set the time for the counter used in the 
PLC program (ladder). 
(Note) This setting value is valid when 
parameter "#6449 bit1" in the 
following "[BIT SELECT]" is set 
to "0". 
0 to 32767