10. PLC Constants
10.1 PLC Timer
278
10. PLC Constants
10.1 PLC Timer
(SETUP PARAM 6. 1/6) to (SETUP PARAM 6. 2/6)
#
PLC device
Item
Details
Setting range
6000
6015
T000
T015
10ms adding
timer <10ms>
timer <10ms>
Set the time for the timer used in the PLC
program (ladder).
program (ladder).
(Note) This setting value is valid when
parameter "#6449 bit0" in the
following "[BIT SELECT]" is set
to "0".
following "[BIT SELECT]" is set
to "0".
0 to 32767 (
×10ms)
6016
6095
T016
T095
100ms adding
timer <10ms>
timer <10ms>
Set the time for the timer used in the PLC
program (ladder).
program (ladder).
(Note) This setting value is valid when
parameter "#6449 bit0" in the
following "[BIT SELECT]" is set
to "0".
following "[BIT SELECT]" is set
to "0".
0 to 32767 (
×100ms)
6096
6103
T096
T103
100ms
cumulative
timer
<100ms INC>
cumulative
timer
<100ms INC>
Set the time for the timer used in the PLC
program (ladder).
program (ladder).
(Note) This setting value is valid when
parameter "#6449 bit0" in the
following "[BIT SELECT]" is set
to "0".
following "[BIT SELECT]" is set
to "0".
0 to 32767 (
×100ms)
10.2 PLC Counter
(SETUP PARAM 6. 3/6)
#
PLC device
Item
Details
Setting range
6200
6223
C000
C023
Counter
Set the time for the counter used in the
PLC program (ladder).
PLC program (ladder).
(Note) This setting value is valid when
parameter "#6449 bit1" in the
following "[BIT SELECT]" is set
to "0".
following "[BIT SELECT]" is set
to "0".
0 to 32767