12.  Position Switch 
12.2  Canceling the Position Switch 
 
 
286 
Rotary axis 
Setting of dog1 and dog2 
Operation 
Description 
dog1 
< dog2 
 
A signal is output 
between dog1 and 
dog2. 
 
A signal is also output 
when dog1 is negative. 
dog1 
> dog2 
 
A signal is output 
between dog2 and 
dog1. 
⏐dog1 − dog2⏐ ≥ 360 
 
A signal is kept output 
when the difference 
between dog1 and dog2 
exceeds 360 degrees. 
 
12.2  Canceling the Position Switch 
To cancel the position switch‚ enter the number (#75
∗1) of the position switch to be canceled in # ( ) 
of the setting area‚ enter a slash "/" in DATA ( )‚ then press the  INPUT  key. This deletes the axis 
name for the specified position switch‚ thus invalidating the position switch. 
The data specified for <dog1> and <dog2> are still stored in memory. To validate the position switch 
again‚ therefore‚ it is enough to specify the axis name only.