Mitsubishi Electronics C64T ユーザーズマニュアル
12. Position Switch
12.2 Canceling the Position Switch
286
Rotary axis
Setting of dog1 and dog2
Operation
Description
dog1
< dog2
A signal is output
between dog1 and
dog2.
between dog1 and
dog2.
A signal is also output
when dog1 is negative.
when dog1 is negative.
dog1
> dog2
A signal is output
between dog2 and
dog1.
between dog2 and
dog1.
⏐dog1 − dog2⏐ ≥ 360
A signal is kept output
when the difference
between dog1 and dog2
exceeds 360 degrees.
when the difference
between dog1 and dog2
exceeds 360 degrees.
12.2 Canceling the Position Switch
To cancel the position switch‚ enter the number (#75
∗1) of the position switch to be canceled in # ( )
of the setting area‚ enter a slash "/" in DATA ( )‚ then press the INPUT key. This deletes the axis
name for the specified position switch‚ thus invalidating the position switch.
The data specified for <dog1> and <dog2> are still stored in memory. To validate the position switch
again‚ therefore‚ it is enough to specify the axis name only.
name for the specified position switch‚ thus invalidating the position switch.
The data specified for <dog1> and <dog2> are still stored in memory. To validate the position switch
again‚ therefore‚ it is enough to specify the axis name only.