Mitsubishi Electronics FR-A700 Manual De Usuario

Descargar
Página de 523
145
Adjustment of Real sensorless vector
control, vector control
4
4.7.2
Excitation ratio (Pr. 854) 
 
Decrease the excitation ratio when you want to improve efficiency under light load. (Motor magnetic noise
decreases.)
Parameter 
Number
Name
Initial Value
Setting Range
Description
854
Excitation ratio
100%
0 to 100%
Set the excitation ratio under no load.
⋅ Note that the rise of output torque becomes slow if
excitation ratio is decreased.
This  function is appropriate for applications as machine
tools which repeat rapid acceleration/deceleration up to
high speed.
REMARKS
⋅ When "1" (magnetic flux with terminal) is set in Pr. 858 Terminal 4 function assignment or Pr. 868 Terminal 1 function assignment, the
Pr. 854 setting is invalid.
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
Excitation
ratio [%]
100
(initial value)
Pr. 854
set value
0
100
Load [%]