U-Line CO2175FF Manual De Usuario

Descargar
Página de 24
12
CO2175FF2175RF
Maintenance
Proper maintenance of your U-Line product will ensure 
efficiency, top performance and long life. The 
maintenance intervals listed are based on normal 
conditions. You may want to shorten the intervals if you 
have pets or other special considerations.
Defrosting
Frost-Free Models
Frost-free models do not produce frost in normal 
operating conditions. 
WARNING
DO NOT use any type of electrical heating device, 
ice pick, knife or other sharp instrument to 
defrost; this could damage the inner lining or 
refrigeration system and void the warranty.
Condenser Cleaning
Interval - Every Three Months
To maintain operational efficiency, keep the front grille 
free of dust and lint and clean the condenser every three 
months. Depending on environmental conditions, more 
or less frequent cleaning may be necessary.
WARNING
Disconnect electric power to the unit before 
cleaning the condenser.
To remove and replace the grille for access to the 
condenser fins, follow this procedure:
Figure 9
1. Disconnect electrical power to the unit.
2. Loosen two screws (Figure 9, 1) completely.
NOTE: Screws are held in the grille by o-ring retainers, 
and will not come free of the grille.
3. Remove the grille.
WARNING
DO NOT touch the condenser fins. The condenser 
fins are SHARP and can be easily damaged.
CAUTION
DO NOT use any type of cleaner on the condenser 
unit.
4. Clean the condenser coil (Figure 9, 2) using a soft 
brush with a “combing” action or vacuum cleaner. Do 
not touch the condenser coil.
5. Position the grille to align the mounting screws with 
the holes in the cabinet.
6. Secure, but do not over-tighten both grille screws.
7. Reconnect power to the unit.
Ice Maker Maintenance
Inlet Screen
Interval - Every Twelve Months
The solenoid valve inlet screen must be cleaned at least 
once each year as follows:
1. Shut off the water at the main supply valve.
2. Pull the unit out to access the back panel.
3. Disconnect electrical power to the unit.
Figure 10
4. Disconnect the hose connector (Figure 10, 1) from the 
water solenoid valve (Figure 10, 2).
5. DO NOT remove the inlet screen from the water 
solenoid valve. Use a tooth brush to gently clean any 
sediment from the inlet screen. 
6. Re-connect the water supply hose connector (Figure 
10, 1) to the water solenoid valve (Figure 10, 2)
Tighten the connector securely.
7. Open the water main supply valve and check for 
leakage at the water hose connection. Ensure that the 
water supply line is not kinked.
8. Reconnect power to the unit before re-installing.
ULIN_0203_A
2
1
2
1
ULIN_0054_A