U-Line CO2175FF Manual De Usuario

Descargar
Página de 24
14
CO2175FF2175RF
Door Alignment Check and Adjustment
IMPORTANT
IMPORTANT
When properly aligned:
• The door will not be flush with the top of the 
cabinet. The top edge of the door will be 1/8 in. 
(3.175 mm) below the cabinet top.
• The door gasket will be firmly in contact with the 
perimeter of the cabinet and not pinched on the 
hinge side of the door.
The following procedure will correct for up to 1/4 in. 
misalignment:
Figure 15
1. Compare the top edge of the door (opposite the 
hinges) to the top edge of the cabinet (Figure 15) and 
note the type (up or down) of adjustment needed.
Figure 16
2. Remove the top hinge pivot pin with a Phillips 
screwdriver (Figure 16) and lift door off bottom hinge 
pin. Be careful not to lose the door closer insert sets. 
Figure 17
3. Turn the door upside down and inspect the hinge plate 
mounting holes. 
• Your plate has slotted mounting holes (Figure 
17, 1). Loosen but do not remove the two hinge 
plate screws.
4. If door edge opposite the hinges needs to move up, 
move plate toward outside of door (Figure 17, 2). If 
door edge needs to move down, move plate toward 
inside of door (Figure 17, 3). Repeat until top edge of 
door is parallel with top of cabinet and tighten screws 
securely (Figure 17, 1)
Figure 18
5. After adjustment is complete, remove the door closers 
from the bottom hinge, clean thoroughly and apply 
petroleum jelly to the mating surfaces of the closers. Be 
sure that bosses on closers (Figure 18, 1) align with 
holes in the door and bottom cabinet hinge plates. 
Mount door and install top hinge pivot pin.
1/8"
(3.175 mm)
ULIN_0016_A
ULIN_0133_A
ULIN_0201_A
1
2
3
1
ULIN_0004_A