Miscellaneous Machine Setups
 
312393G 
 
18 of 50 
3. Press   to accept the value or 
 to retain the 
previous value. 
 
Figure 19:  M2 after Purge Shot Size Prompt 
4. Press   or 
 to enter the purge shot size (in 
grams).  Enter a number with at least as much 
volume as the mixer. 
5. Press   to accept the value or 
 to retain the 
previous value. 
6. Press   twice to return to the Run screen. 
Activating the purge timer automatically activates the 
purge alarm 
.  This is the amount of time before 
the purge timer reaches zero that the machine will 
sound a warning beep to signaling that it is about to 
take a purge shot.  To change the Purge Alarm value; 
From the Run screen, press 
, then press 
, and then 
press 
 once.  The following screen will be displayed. 
 
Figure 20:  M2 after Purge Alarm Selection 
1. Press  .   
2. Press   or 
 to enter the purge alarm duration 
(in seconds).  The minimum value is 2 seconds, 
and a maximum of 59 seconds or the value of the 
purge timer if the timer is more than 59 seconds. 
3. Press   to accept the value or 
 to retain the 
previous value. 
4. Press   twice to return to the Run screen. 
Cycle Counter and Silent Mode Control (M3) 
Resetting the Cycle Counter: 
The cycle counter shown on the Run screen, see Figure 
6, shows the number of pump cycles since the last time 
the cycle counter was reset.  To reset the cycle counter: 
From the Run screen, press 
, then press 
, and then 
press 
 2 times.  The following screen will be displayed. 
 
Figure 21: M3 Cycle Counter and Silent Mode Control 
Key: 
A  Total Pump Cycle Counter Value (Not Resettable) 
B  Resettable Cycle Counter Value 
C  Current Silent Mode State ICON  
 Silent Mode Off 
 Silent Mode On  
D   Reset Cycle Counter ICON 
E  Toggle Silent Mode ICON. 
I  Screen Number (M3) 
 & 
 keys will navigate to adjacent screens. 
1. Press  . 
2. Press   to accept the value or 
 to retain the 
previous value.  
3. Press   twice to return to the Run screen. 
Silent Mode Operation: 
The default setting is 
, Silent Mode Off, where audio 
feedback is provided when a valid key (1 short tone), or 
an invalid key (3 short tones) is pressed. 
In 
, Silent Mode On, audio feedback is not provided.  
Silent Mode On has no effect on the audio sounds 
provided for the purge timer alarm, an error code, or 
when power is initially applied to the machine. 
To toggle or change the silent mode: 
From the Run screen, press 
, then press 
, and 
then press 
 2 times.  Screen M3, see Figure 21, will 
be displayed. 
1. Press   or 
2. Press   to accept the change or 
 to retain the 
previous setting. 
3. Press   twice to return to the Run screen.