Graco PR70 Manual De Usuario
Miscellaneous Machine Setups
312393G
20 of 50
Figure 26: Tank Level and
(C6)
Key:
A Current Tank Level Mode
A Current Tank Level Mode
= OFF,
= ON
B Current level
= OFF
= 20% change before warning
= 40% change before warning
= 60% change before warning
= 40% change before warning
= 60% change before warning
D Turn ON / OFF Tank Level Sensing ICON
E Change Level ICON
I
I
Screen Number (C6)
J
&
keys will navigate to adjacent screens.
To turn the Tank Level Sensors On/Off:
1. Press or
.
2. Press to accept the change or
to retain the
previous setting.
3. Press twice to return to the Run screen.
To turn the Velocity Change On/Off:
1. Press .
2. Press to accept the change or
to retain the
previous setting.
3. Press twice to return to the Run screen.
Password Setup / Clearing (C5)
The machine has the capability to limit access to the
Maintenance and Calibration screens. The password
option can be configured into 1 of the following 3
possibilities:
Maintenance and Calibration screens. The password
option can be configured into 1 of the following 3
possibilities:
a. No Password (default configuration, when machine
shipped): All users can access all setup screens to
configure the system.
configure the system.
b. One password (“
”): Allows access to both the
maintenance and calibration screens (
+
).
c. Two passwords:. One password allows access to
both the calibration and maintenance screen (
=
+
). The second password only allows
access to the maintenance screens (
=
).
To alter the password configuration:
From the Run screen, press
, then press
, and then
press
4 times. The following screen will be displayed.
Figure 29: C5 Screen with at least 1 Password
Configured
Key:
A Administrative Password ICON
B Access Indicator for Administrative Password
D Entry Status (Only filled after password change).
E Maintenance ONLY Password ICON
F Access Indicator for Maintenance ONLY Password
G Administrative Password Set/Clear ICON
H Maintenance ONLY Password Set/Clear ICON
I Screen Number (C5)
J
A Administrative Password ICON
B Access Indicator for Administrative Password
D Entry Status (Only filled after password change).
E Maintenance ONLY Password ICON
F Access Indicator for Maintenance ONLY Password
G Administrative Password Set/Clear ICON
H Maintenance ONLY Password Set/Clear ICON
I Screen Number (C5)
J
&
keys will navigate to adjacent screens.
Setting/Clearing an Administrative Password:
1. Press . The following screen will appear.