Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances. Save 
Installation Instructions for electrical inspector’s use.
It is the customer’s responsibility to contact a qualified electrical 
installer, and to ensure that the electrical installation is adequate 
and in conformance with National Electrical Code, ANSI/NFPA 70 
(latest edition), or CSA Standards C22.1-94, Canadian Electrical 
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local 
codes and ordinances.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
This fan is suitable for use with solid state speed controls.
A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is 
required.
Check with a qualified electrician if you are not sure the 
downdraft vent is properly grounded.
The downdraft vent must be connected with copper wire 
only.
The downdraft vent should be connected directly to the 
circuit breaker (or fused disconnect) box through flexible 
armored or nonmetallic sheathed copper cable. Allow some 
slack in the cable so the downdraft vent can be moved if 
servicing is ever necessary.
Wire sizes (copper wire only) and connections must conform 
with the rating of the appliance as specified on the model/
serial rating plate located on the front of the downdraft vent 
above the wiring box cover.
Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 
Standards C22.1-94, Canadian Electrical Code, Part 1 and 
C22.2 No. 0-M91 (latest edition) and all local codes and 
ordinances.
Two UL listed or CSA approved ½" (12.7 mm) conduit 
connectors.
A wiring diagram is located on the downdraft vent base 
above the power control board cover.
Venting Requirements
IMPORTANT: Make sure there is proper clearance within the wall 
or floor before making exhaust vent cutouts.
Use heavy (rigid) metal vent.
Venting system must terminate to the outside.
Do not terminate the vent system in an attic or other enclosed 
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Do not install 2 elbows together.
Do not use plastic or metal foil vent.
The length of vent system and number of elbows should be 
kept to a minimum to provide efficient performance.
Use no more than three 90° elbows 
Make sure there is a minimum of 24" (61 cm) of straight vent 
between the elbows if more than one elbow is used.
Use clamps to seal all joints in the vent system.
Use caulking tape to seal the exterior wall or floor opening 
around cap.
Do not cut joist or stud. If vent cutout falls over a joist or stud, 
a supporting frame must be constructed.
Flexible metal vent is not recommended. If it is used, calculate 
each foot of flexible vent as 2 ft (0.6 m) of rigid metal vent.
Flexible elbows count twice as much as standard elbows.
Recommended vent system length: 
For either interior-mounted or exterior-mounted blower 
installations, the vent system length should not exceed the 
maximum lengths listed in the Maximum Length of Vent System 
chart. See “Calculating Vent System Length” in the “Venting 
Methods - Interior Mounted Vent Motor Only” section.