To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.
Example Vent System
The following example falls within the maximum vent length of 
35 ft (8.9 m).
Install Vent System
1. Place cardboard or similar material on top of a flat surface 
where you can easily assemble the downdraft vent system. 
2. Remove parts packages, downdraft vent and blower box 
from the carton. 
3. Remove all shipping materials, tape and film from the 
downdraft vent and blower box.
4. Remove screws from each side of the vent. Attach the left 
and right side overcounter support brackets to the downdraft 
vent and push up to align the screw holes. Use screws to 
secure the brackets.
Vent Piece
6" (15.2 cm) Round
45° elbow
2.5 ft
(0.8 m) 
90° elbow
5.0 ft
(1.5 m)
6" (15.2 cm) 
wall cap
0.0 ft
(0.0 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm) 
to 6" (15.2 cm) transition
4.5 ft
(1.4 m)
6" (15.2 cm) to 3
¹⁄₄" x 10" 
(8.3 cm x 25.4 cm) transition
1 ft
(0.3 m)
3
¹⁄₄" x 10" (8.3 cm x 25.4 cm) 
to 6" (15.2 cm) 90° elbow 
transition
5.0 ft
(1.5 m)
6" (15.2 cm) to 3
¹⁄₄" x 10" 
(8.3 cm x 25.4 cm) 90° elbow 
transition
5.0 ft
(1.5 m)
A. Blower motor
B. Transition
C. 90° elbows
D. 6" backdraft damper (supplied)
A
B
C
6 ft 
(1.8 m)
2 ft (0.6 m)
D
2 - 90° elbow
= 10.0 ft (3 m)
1 - wall cap
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
Transition
= 4.5 ft (1.4 cm)
Length of 6" (15.2 cm) 
system
= 22.5 ft (6.8 m)
A. Overcounter support bracket
B. Blower motor box
C. Overcounter support bracket screw
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
downdraft vent.
Failure to do so can result in back or other injury.
A
B
C