U-Line CLR2060SSHR Manual De Usuario

Descargar
Página de 118
25
Design 
Features 
Performance 
CO2075FF/2075RF & U-CO29FF MODELS
d. Defrost drain line not in drain pan.
e. Crack in water line.
13. Water leak (inside unit)
Cause
a. Ice maker assembly fill cup obstructed.
b. Fill ice cup and fill tube out of alignment.
c. Water level too high.
d. Defrost drain plugged.
14. Excessive frost build-up
Cause
a. Door gasket not sealing properly.
b. Door out of alignment.
c. Water soaked cabinet insulation.
d. Light stays on when door is closed.
15. Noisy
Cause
a. Copper refrigeration tube touching cabinet.
b. Fan blade touching shroud.
c. Fan blade obstruction (wiring, foam insulation,
packaging material).
16. Ice build-up in drain trough or drainage 
problem.
Cause
a. Obstructed drain cup or tube.
b. Evaporator not touching drain trough.
c. Kinked drain tube.
d. Drain trough spout and drain cup not aligned.
17. Unit will not defrost
Cause
a. Bypass valve not vertical (will not operate).
b. Bypass coil defective.
c. Defrost timer defective.
d. Bypass valve defective.
18. Fresh food temperature too cold
Cause
a. Ice bucket not fully inserted.
b. Freezer temperature control set too cold.
d. Position drain line in drain pan.
e. Replace water line.
Remedy
a. Remove obstruction.
b. Align fill tube and fill cup.
c. Adjust water level.
d. Ice in drain trough (refer to #16).
Remedy
a. Adjust door hinges or replace door gasket.
b. Align door hinges.
c. Replace foamed cabinet assembly 
(factory repair only).
d. Repair or adjust light bracket.
Remedy
a. Carefully adjust tubing.
b. Adjust fan mounting or shroud.
c. Remove obstruction.
Remedy
a. Clear obstruction.
b. Reposition evaporator to contact drain trough
along entire length.
c. Reposition drain tube.
d. Align drain trough and drain cup.
Remedy
a. Align bypass valve and coil assembly.
b. Replace bypass valve.
c. Replace defrost timer.
d. Replace bypass valve.
Remedy
a. Push ice bucket in place.
b. Adjust freezer control to warmer setting 
(counterclockwise).