27
Design 
Features 
Performance 
REPLACING ICE MAKER ASSEMBLY
1. Unplug 
unit.
2. 
Disconnect ice maker wire harness at plug (1).
3. 
Remove control capillary tube from sensing tube on ice maker assembly (2).
4. 
Remove water inlet tube.
5. 
Remove front cover (3).
6. 
Advance ejector blade to the 3 o’clock position by turning the 5/16" hex head on the small brass 
gear counterclockwise (4).
7. 
Remove three screws from wall of freezer housing (5).
8. 
Remove ice maker assembly.
9. 
Install new ice maker assembly.
10. Reconnect plug.
11.  Insert control capillary tube into ice maker sensing tube.
12. Insert water inlet tube.
13. Apply Permagum
®
to all exit holes.
14.  Install back panel.
15. Plug in unit and test.