Bunn Axiom Manual De Usuario
Page 15
PROBABLE CAUSE
REMEDY
PROBLEM
TROUBLESHOOTING (cont.)
Check plumbing and shut-off
valves
valves
A) Wait for the brewer to heat
to the proper temperature
to the proper temperature
B) Disable the BREW LOCK-
OUT function. Refer to program-
ming section for procedure.
OUT function. Refer to program-
ming section for procedure.
Turn on
Service required
Service required
Service required
1. No water
2. Water temperature in the
tank does not meet the ready
temperature.
tank does not meet the ready
temperature.
3. "ENABLE BREW ON/OFF"
switch not on.
switch not on.
4. Brew switch
5. Brew valve
6. Control Board
Brew cycle will not start
Spitting or unusual steaming
from sprayhead or air vent.
from sprayhead or air vent.
1. Lime buildup
2. Temperature probe
3. Control Board
Refer to cleaning section.
Service required
Service required
Inconsistent beverage level
Refer to cleaning section.
Service required
1. Lime buildup
2. Brew valve
Dripping from sprayhead.
Water overflows filter.
Beverage overflows decanter
Service required
BUNN paper filters should be
used for proper extraction
used for proper extraction
Replace sprayhead
The brew cycle should be start-
ed only with an empty decanter
under the funnel.
ed only with an empty decanter
under the funnel.
Adjust the brew volume, cali-
brate sprayhead as required to
achieve the desired volume for
each brew cycle.
brate sprayhead as required to
achieve the desired volume for
each brew cycle.
1. Brew valve
1. Type of paper filter
2. No sprayhead
1. Beverage left in decanter from
previous brew
previous brew
2. Brew volume adjustment
41154 041708