Bunn Axiom Manual De Usuario

Descargar
Página de 17
Page 17
PROBABLE CAUSE
REMEDY
PROBLEM
TROUBLESHOOTING (cont.)
Brewer  is  making  unusual 
noises.
Service required.
Plumbing  lines  should  not  be 
resting on the countertop.
The brewer must be connected 
to a cold water line.  Water pres-
sure to the brewer must not be 
higher  than  90  psi  (620  kPa).  
Install a regulator if necessary 
to lower the working pressure 
to  approximately  50  psi  (345 
kPa).
Service required.
1. Solenoids vibrating
2. Plumbing lines
3. Water supply
4. Tank heaters
"CHECK    SPRAYHEAD  FOR 
LIME"  -  "CHECK  FITTINGS 
FOR LIME"
Refer to cleaning section.
Refer to cleaning section.
Service required.
1. Lime buildup in sprayhead
2. Lime buildup in brew valve
3. Lime buildup in brew tank
"WARNING  INACCURATE 
FLOW"  -  "TOO  MUCH  LIME 
PLEASE REPAIR"
Refer to cleaning section.
Refer to cleaning section.
Service required.
1. Lime buildup in sprayhead
2. Lime buildup in brew valve
3. Lime buildup in brew tank
"WARNING VERY LOW FLOW" 
- "PLEASE REPAIR"
Refer to cleaning section.
Refer to cleaning section.
Service required.
1. Lime buildup in sprayhead
2. Lime buildup in brew valve
3. Lime buildup in brew tank
41154 041708