TROUBLESHOOTING (cont.)
Problem
Spitting or unusual steaming from 
sprayhead.
Warmer plates too hot, solenoid 
coil smoking, or water in tank heats 
excessively fast.
Inconsistent beverage level in de-
canter.
Dripping from sprayhead.
Probable Cause
1. Control Thermostat
2. Lime build-up
CAUTION
Tank and tank components should 
be delimed regularly depending on 
local water conditions.  Excessive 
mineral build-up on stainless steel 
surfaces can initiate corrosive reac-
tions resulting in serious leaks.
1. Brewer wired to wrong voltage
1. Improper water pressure
2. Syphon system
1. Syphon system
2. Solenoid Valve
Remedy
Refer to Service - Control Thermo-
stat for testing procedures.  See 
page 13.
Inspect the tank assembly for ex-
cessive lime deposits.  Delime as 
required.
Refer to Electrical Requirements - 
Page 4.
Check the operating water pressure 
to the brewer.  It must be between 
20 and 90 psi.
Water should flow freely from the 
sprayhead  and then stop abruptly.  
The brewer must be level from front-
to-back to syphon properly.
Water should flow freely from the 
sprayhead and then stop abruptly.  
The brewer must be level from front-
to-back to syphon properly.
Refer to Service - Solenoid Valve for 
testing procedures.  See page 20.
32430 121699