TROUBLESHOOTING (cont.)
Problem
Beverage overflows decanter.
Weak beverage.
Brewer is making unusual noises.
Probable Cause
1. Beverage left in decanter
1. Type of paper filters
2. Coffee
3. Sprayhead
4. Funnel loading
5. Water temperature
1. Solenoid Valve
2. Plumbing lines
3. Water supply
Remedy
The brew cycle should be started 
only with an empty decanter under 
the funnel.
BUNN® paper filters should be used 
for proper extraction.
A sufficient quantity of fine or drip 
grind coffee should be used for 
proper extraction.
B.O.M. sprayhead #01082.0000 
should be used to properly wet the 
bed of ground coffee in the funnel.
The BUNN® paper filter should be 
centered in the funnel and the bed of 
coffee leveled by gentle shaking.
Place a funnel over an empty de-
canter on the warmer beneath the 
sprayhead.  Place the On/Off brew 
station warmer switch in the upper 
position, press the start switch, 
and check the water temperature 
immediately below the sprayhead 
with an accurate thermometer.  The 
reading should not be less than 195° 
F.  Adjust the control thermostat 
slightly clockwise to increase the 
water temperature.
The nut on top of the solenoid valve 
must be tight or it will vibrate during 
operation.
Plumbing lines should not rest on 
the counter top.
(A) The brewer must be connected 
to a cold water line.
(B) Water pressure to the brewer 
must not be higher than 90 psi.  
Install a regulator if necessary to 
lower the working pressure to ap-
proximately 50 psi.