TROUBLESHOOTING GUIDE - 
POWER HEAD LEDs
 
FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM
Power Head LED
Possible Problem
Solution
Round LED
Long LED
OFF
OFF
Normal operation
None required
No response from unit
Check power supply
Contact a trained door system 
technician
ON/RED/
STEADY
ON/RED/
STEADY
Limits NOT set properly
Reprogram Limits, see pages 6-7
ON/RED/
FLASHING
ON/RED/
FLASHING
Program error
Unplug unit, wait 5 seconds, plug in
Component failure
Contact a trained door system 
technician
ON/BLUE/
FLASHING
OFF
Remote NOT programmed
Program remote, see page 8
ON/PURPLE/
FLASHING
OFF
IntelliCode® 1 remote NOT 
programmed
Program remote using IntelliCode® 
2 remote, see page 8, then program 
IntelliCode® 1 remote using 
instructions on page 9
ON/RED/
FLASHING
OFF
Safe-T-Beam® physical 
obstruction
Remove obstruction, recheck unit
Safe-T-Beam® signal 
interference
Check alignment of Safe-T-Beam® pair 
and nearest other Safe-T-Beam® pair
OFF
ON/RED/
FLASHING
Door contact in up or down 
travel
Remove obstruction
Door component failure 
detected
Check door spring, track, rollers, hinges 
and fixtures
OFF
ON/RED/
STEADY
Thermal cutout
DO NOT unplug unit  
Wait until LED clears before operating
TROUBLESHOOTING GUIDE - 
OPERATION (CONTINUED) ..................................................................... FOR HELP-1.800.354.3643
PROBLEM
WHAT TO DO
Door opener starts for 
no reason.
•   Check "CLOSE" Limit setting.  See pages 6-7.
•   Button stuck on wall console or remote.
•   Was a remote lost or stolen? Erase all remotes from power head memory and program 
new remotes.  See page 8.
Noisy operation.
•   Be sure all door fasteners are tight.
•   Be sure garage door is in good repair, properly lubricated and balanced.
•   Be sure opener is in good repair.
Door opener runs 
slow
•   Check operating condition of door.  See pages 17 and 18 . Door may need professional 
repair/adjustment.
•   Is this opener installed on a one piece door?  Normal speed for one piece door is 
lowest speed setting.
•   If carriage travel is less than 6 feet, opener configures programming for a one piece 
door.
•   Check door speed.  See page 22.