ADJUSTMENT GUIDE - 
FORCE SETTINGS 
FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM
Force settings are pre-programmed at the factory 
and "learned" during the Open/Close Limit settings 
steps.  For normal use Force settings should not 
need adjustment with this unit.
However, conditions that might suggest an 
adjustment is necessary are;
Doors with very stiff weather seals
Doors that start down, then STOP and reverse 
before it is closed
Doors that start up, but STOP before it is 
completely open
Force Level
Power Head LEDs
Round LED
Long LED
Default LED display is the current Force setting
LED indicator colors                                       
 OFF,  
 Blue,  
 Purple,  
 Red
Force Level LED indicator colors
Force Level 1
Blue
ON
 
 
OFF
Force Level 2
OFF
 
 
Blue
ON
Force Level 3
Blue
ON
 
 
Blue
ON
Force Level 4
Purple
ON
 
 
OFF
Force Level 5
OFF
 
 
Purple
ON
Force Level 6
Purple
ON
 
 
Purple
ON
Force Level 7
Red
ON
 
 
OFF
Force Level 8
OFF
 
 
Red
ON
Force Level 9
Red
ON
 
 
Red
ON
 
CAUTION
 
Door closing force is FACTORY set and requires no 
adjustment for normal operation.
•  Never increase the door closing force to 
compensate for a damaged door or a binding 
door track.
•  Never adjust force to compensate for a broken 
door spring.
•  Perform monthly CONTACT REVERSE TEST as 
described on page 1
.
CHANGE FORCE SETTING
Use this guide to ADJUST power head FORCE settings.
NOTE: There are nine (9) force levels.  Not all force 
levels are available on all models.
Some models come with a reduced range of force 
levels.  On these models you can adjust Force 
settings only within the reduced range.
1. Press 
PROGRAM
SET
 on the power head and hold till both 
lights turn steady ON.  Release button.  
Lights go out and Round BLUE light comes ON.
2. Press   three times and Round RED light comes 
ON.  (These Force settings do not scroll.) 
3. Press 
PROGRAM
SET
 once to enter the Force Programming 
menu.  The power head LEDs will display the 
current Force setting.  See table below.
4. Press   to raise or   to lower UP Force settings 
within the available range.  (If lower UP Force 
setting is good skip to Step 5.)
5. Press 
PROGRAM
SET
 to set UP Force level.
6. Press   to raise or   to lower DOWN Force 
settings within the available range.  (If lower 
DOWN Force setting is good skip to Step 7.)
7. Press 
PROGRAM
SET
 to set DOWN Force level and to exit Force 
menu.  Both LEDs flash BLUE to confirm.