Gun Overview
Error Display
If the Smart module loses communication with
the power supply, the Error display appears, the
Hz indicator turns red, and the Smart module is
disabled. See Fig. 3, and Table 1 on page 11.
This can occur in Operating Mode or Diagnostic
Mode. See
.
Communication must be restored to make the Smart
module functional.
NOTE: It takes 8 seconds for the Error display to
appear. If the gun has been disassembled, wait 8
seconds before spraying to ensure that an Error
condition has not occurred.
NOTE: If there is no power to the gun, the Error
display will not appear.
Figure 3 Error Display
Adjusting the Low Voltage Setting
The low voltage setting is user adjustable. To access
the low voltage setting screen when in Operating
Mode, press the LO SET button (LS) momentarily.
The screen will display the current low voltage
setting. See Fig. 4, and Table 1 on page 11. The
possible ranges are:
• 85 kV guns: 40–85 kV
• 60 kV guns: 30–60 kV
Set the Voltage Adjustment switch (VA) to LO. Press
the LO SET button repeatedly to increase the setting
in increments of 5. When the display reaches the
maximum setting it will return to the minimum setting
for your gun. Continue pressing the button until you
reach the desired setting.
NOTE: After 2 seconds of inactivity the display will
return to the Operating Screen.
NOTE: The low voltage setting may be locked. See
Figure 4 Low Voltage Setting Screen (Unlocked)
Lock Symbol
The low voltage setting may be locked. When locked,
an image (LK) appears on the screen. See Fig. 5,
and Table 1 on page 11.
• When in HI mode, the low voltage setting is always
locked. The lock symbol will appear when the LO
SET button is pressed.
• In LO mode, the lock symbol will only
appear if the lock is enabled. See
to lock
or unlock the low voltage setting.
Figure 5 Low Voltage Setting Screen (Locked)