Graco 3A2495C Manual De Usuario

Descargar
Página de 68
Gun Overview
Smart Guns
The Smart Gun module displays spraying voltage,
current, alternator speed, and the voltage setting (low
or high). It also allows the user to change to a lower
spraying voltage. The module has two modes:
• Operating Mode
• Diagnostic Mode
Operating Mode
Bar Graph
See Fig. 2, and Table 1 on page 11. The Operating
Mode displays gun data during normal spraying. The
display uses a bar graph to show the voltage level in
kiloVolts (kV) and the current level in microAmperes
(uA). The bar graph range is from 0 to 100% for each
value.
If the uA bar graph LEDs are blue, the gun is ready
to spray. If the LEDs are yellow or red, the current is
too high. The fluid may be too conductive, or see
for other possible
causes.
Hz Indicator
The Hz indicator functions the same as the ES
indicator on standard guns. The indicator lights to
show the alternator speed status, and has three
colors:
• Green indicates the alternator speed is correct.
• If the indicator changes to amber after 1 second,
increase the air pressure.
• If the indicator changes to red after 1 second,
reduce the air pressure.
Voltage Adjustment Switch
The voltage adjustment switch (VA) allows the
operator to change from low to high voltage.
• The high voltage setting is determined by the
maximum voltage of the gun and is not adjustable.
• The low voltage indicator (LO) lights
when the switch is set to LO. The low
voltage setting is user adjustable. See
NOTE: If the Error display appears, the Smart module
has lost communication with the power supply. See
for further information.
Figure 2 Smart Gun Module in Operating Mode
3A2495C
9