Troubleshooting 
10
310824D
Troubleshooting
WARNING
Read Electric Shock Warning, page 3, Burn Hazard 
Warning
, page 4 and Pressure Relief Procedure
page 8.
 Problem
What To Check
(If check is OK, go to next check)
What To Do
(When check is not OK, refer to this column)
Motor Won’t Operate
Basic Fluid Pressure
1.
Pressure control knob setting. 
Motor will not run if set at mini-
mum (fully counter-clockwise).
Slowly increase pressure setting to see if motor 
starts.
2.
Spray tip or fluid filter may be 
clogged.
Relieve pressure, page 8. Then clear clog or 
clean gun filter. Refer to gun instruction manual, 
309639.
Basic Mechanical 
1.
Pump frozen or hardened paint
Thaw sprayer if water or water-based paint has 
frozen in sprayer. Place sprayer in warm area to 
thaw. Do not start sprayer until thawed com-
pletely. If paint hardened (dried) in sprayer, 
replace pump packings. See page 14Dis-
placement Pump Replacement
.
2.
Displacement pump connecting 
rod pin. Pin must be completely 
pushed into connecting rod and 
retaining spring must be firmly in 
groove or pump pin.
Push pin into place and secure with spring 
retainer. See page 14Displacement Pump 
Replacement
.
3.
Motor. Remove drive housing 
assembly. See page 16Drive 
Housing Replacement
. Try to 
rotate fan by hand.
Replace motor if fan won’t turn. See page 27
Motor Replacement.